MM3 MOTOR MANAGER 3 – INSTRUCTION MANUAL
MODBUS MEMORY MAP
CHAPTER 8: COMMUNICATIONS
30136
135
0087
Phase B current (fast
update)
---
---
**
F1
---
30137
136
0088
Phase C current (fast
update)
---
---
**
F1
---
30138
137
0089
Ground current (fast
update)
---
---
0.1
×
A
F1
---
30139
138
008A
Voltage (fast update)
---
---
V
F1
---
30140
139
008B
Current display line
---
---
---
F1
---
30141
140
008C
Current display mode
---
---
---
F1
---
30142
141
008D
...Reserved...
...
...
...
...
...
30143
142
008E
...Reserved...
...
...
...
...
...
30144
143
008F
...Reserved...
...
...
...
...
...
30145
144
0090
Message buffer characters
1 and 2
---
---
ASCII
F10
---
30146
145
0091
Message buffer characters
3 and 4
---
---
ASCII
F10
---
30147
146
0092
Message buffer characters
5 and 6
---
---
ASCII
F10
---
30148
147
0093
Message buffer characters
7 and 8
---
---
ASCII
F10
---
30149
148
0094
Message buffer characters
9 and 10
---
---
ASCII
F10
---
30150
149
0095
Message buffer characters
11 and 12
---
---
ASCII
F10
---
30151
150
0096
Message buffer characters
13 and 14
---
---
ASCII
F10
---
30152
151
0097
Message buffer characters
15 and 16
---
---
ASCII
F10
---
30153
152
0098
Message buffer characters
17 and 18
---
---
ASCII
F10
---
30154
153
0099
Message buffer characters
19 and 20
---
---
ASCII
F10
---
30155
154
009A
Message buffer characters
21 and 22
---
---
ASCII
F10
---
30156
155
009B
Message buffer characters
23 and 24
---
---
ASCII
F10
---
30157
156
009C
Message buffer characters
25 and 26
---
---
ASCII
F10
---
30158
157
009D
Message buffer characters
27 and 28
---
---
ASCII
F10
---
30159
158
009E
Message buffer characters
29 and 30
---
---
ASCII
F10
---
30160
159
009F
Message buffer characters
31 and 32
---
---
ASCII
F10
---
30161
160
00A0
Message buffer characters
33 and 34
---
---
ASCII
F10
---
30162
161
00A1
Message buffer characters
35 and 36
---
---
ASCII
F10
---
30163
162
00A2
Message buffer characters
37 and 38
---
---
ASCII
F10
---
Table 8–2: Modbus Memory Map (Sheet 5 of 28)
Modicon
Address
Description
Range
Step
Units Format
Default
dec.
hex
* – Maximum setpoint value and 65535 represent OFF; ** – 1/phase current scale factor
×
A; *** – 101
represents unlimited;
† – Minimum setpoint value represents OFF; ~ – 0.1
×
A when high resolution mode is disabled;
0.01
×
A when enabled
Содержание MM3
Страница 8: ...vi MM3 MOTOR MANAGER 3 INSTRUCTION MANUAL TABLE OF CONTENTS ...
Страница 11: ...CHAPTER 1 INTRODUCTION OVERVIEW MM3 MOTOR MANAGER 3 INSTRUCTION MANUAL 1 3 Figure 1 1 Functional block diagram ...
Страница 18: ...1 10 MM3 MOTOR MANAGER 3 INSTRUCTION MANUAL TECHNICAL SPECIFICATIONS CHAPTER 1 INTRODUCTION ...
Страница 80: ...4 18 MM3 MOTOR MANAGER 3 INSTRUCTION MANUAL CHASSIS MOUNT UNITS CHAPTER 4 SOFTWARE ...
Страница 124: ...5 44 MM3 MOTOR MANAGER 3 INSTRUCTION MANUAL S7 TESTING CHAPTER 5 SETPOINTS ...
Страница 198: ...8 54 MM3 MOTOR MANAGER 3 INSTRUCTION MANUAL MODBUS MEMORY MAP CHAPTER 8 COMMUNICATIONS ...
Страница 220: ...10 14 MM3 MOTOR MANAGER 3 INSTRUCTION MANUAL GE MULTILIN WARRANTY CHAPTER 10 MISCELLANEOUS ...