8–22
350 FEEDER PROTECTION SYSTEM – COMMUNICATIONS GUIDE
MODBUS MEMORY MAP
CHAPTER 8: MODBUS MEMORY MAP
LOGIC ELEMENTS (TRIGGERS & BLOCKS)
41227
4CA
LE14 Trigger Logic
0
1
1
---
FC149
0
1
41228
4CB
LE14 Block Logic
0
1
1
---
FC149
0
1
LOGIC ELEMENTS
41230
4CD
Timer 15 Pickup Delay
0
60000
1
ms
F1
0
1
41231
4CE
Timer 15 Dropout Delay
0
60000
1
ms
F1
0
1
41232
4CF
LE 15 Function
0
4
1
---
FC205
0
1
41233
4D0
LE 15 Asserted
0
1
1
---
FC103
0
1
41234
4D1
LE 15 Relays
0
0x7F
1
---
FC198
0
1
LOGIC ELEMENTS (TRIGGERS & BLOCKS)
41235
4D2
LE15 Trigger Logic
0
1
1
---
FC149
0
1
41236
4D3
LE15 Block Logic
0
1
1
---
FC149
0
1
LOGIC ELEMENTS
41238
4D5
Timer 16 Pickup Delay
0
60000
1
ms
F1
0
1
41239
4D6
Timer 16 Dropout Delay
0
60000
1
ms
F1
0
1
41240
4D7
LE 16 Function
0
4
1
---
FC205
0
1
41241
4D8
LE 16 Asserted
0
1
1
---
FC103
0
1
41242
4D9
LE 16 Relays
0
0x7F
1
---
FC198
0
1
LOGIC ELEMENTS (TRIGGERS & BLOCKS)
41243
4DA
LE16 Trigger Logic
0
1
1
---
FC149
0
1
41244
4DB
LE16 Block Logic
0
1
1
---
FC149
0
1
CONTACT INPUT ASSIGNMENT
41380
563
Remote Reset
0
0x1DF
1
---
F89
0
1
41386
569
Remote Open
0
0x1DF
0
---
F89
0
1
41387
56A
Remote Close
0
0x1DF
0
---
F89
0
1
41388
56B
Breaker Connected
0
0x49
0
---
FC204B 0
1
41389
56C
Breaker 52a Contact
0
0x40
0
---
FC204A 0
1
41390
56D
Breaker 52b Contact
0
0x41
0
---
FC204C 0
1
41391
56E
Local Mode
0
0x1DF
0
---
F89
0
1
41404
57B
Set Group 2 Active
0
0x1DF
1
---
F89
0
1
41405
57C
Block Group Change
0
0x1DF
1
---
F89
0
1
CONTACT INPUT NAMES (9 TO 10)
41435
59A
Input Name 9
---
---
---
---
F22
Input 9
9
41444
5A3
Input Name 10
---
---
---
---
F22
Input 10
9
CONTACT INPUTS
41454
5AD
Input 9 Debounce Interval
1
64
1
ms
F1
2
1
41455
5AE
Input 10 Debounce Interval
1
64
1
ms
F1
2
1
41456
5AF
Input 1 Debounce Interval
1
64
1
ms
F1
2
1
41457
5B0
Input 2 Debounce Interval
1
64
1
ms
F1
2
1
41458
5B1
Input 3 Debounce Interval
1
64
1
ms
F1
2
1
41459
5B2
Input 4 Debounce Interval
1
64
1
ms
F1
2
1
41460
5B3
Input 5 Debounce Interval
1
64
1
ms
F1
2
1
41461
5B4
Input 6 Debounce Interval
1
64
1
ms
F1
2
1
41462
5B5
Input 7 Debounce Interval
1
64
1
ms
F1
2
1
41463
5B6
Input 8 Debounce Interval
1
64
1
ms
F1
2
1
41465
5B8
Select DC Voltage
0
3
1
---
FC123
2
1
Modbus
Address
Hex
Address
Description
Min
Max
Step Units
Format
Code
Factory
Default
Size in
Words
Содержание ML Series 350
Страница 4: ......
Страница 8: ...iv 350 FEEDER PROTECTION SYSTEM COMMUNICATIONS GUIDE ...
Страница 10: ...1 2 350 FEEDER PROTECTION SYSTEM COMMUNICATIONS GUIDE CHAPTER 1 COMMUNICATIONS INTERFACES ...
Страница 108: ...4 38 350 FEEDER PROTECTION SYSTEM COMMUNICATIONS GUIDE SR3 IEC 61850 GOOSE DETAILS CHAPTER 4 SR3 IEC61850 GOOSE ...
Страница 138: ...4 68 350 FEEDER PROTECTION SYSTEM COMMUNICATIONS GUIDE IEC 61850 COMMON DATA CLASS CHAPTER 4 SR3 IEC61850 GOOSE ...
Страница 148: ...5 10 350 FEEDER PROTECTION SYSTEM COMMUNICATIONS GUIDE OPC UA POINT LISTS CHAPTER 5 OPC UA COMMUNICATION STANDARD ...
Страница 152: ...6 4 350 FEEDER PROTECTION SYSTEM COMMUNICATIONS GUIDE MODBUS PROTOCOL CHAPTER 6 USB INTERFACE ...
Страница 300: ...10 8 350 FEEDER PROTECTION SYSTEM COMMUNICATIONS GUIDE MODBUS USER MAP CHAPTER 10 USING THE MODBUS USER MAP ...