4 9
STATUS CODE
-94
D E S C R I P T I O N
No
MEMORY
R E C A L L
C O N T R O L
T Y P E
TMM
STATUS CODE
-93
D E S C R I P T I O N
No
MEMORY
R E C A L L
C O N T R O L
T Y P E
TMM
Figure 1
Figure 1
SYMPTOM
Status code flashes on and off.
POSSIBLE CAUSE
User defined status code is displayed by switch closure or
motor brush sensor closure to negative.
See OEM instruction manual for corrective action
required.
Other Causes:
Terminal 5 and 6 shorted to negative.
Defective input switch (shorted).
Defective TMM card.
NOTE: When SCR pump control is used with internal
TMM function, input terminal is PA1 and PA2 on pump
logic card.
STATUS INDICATION CRITERIA
This status code is displayed when the voltage at
terminal 5 and 6 of TMM is at zero volts.
User defined status code - see OEM instructions manual.
User defined status code - see OEM instructions manual.
SYMPTOM
Status code flashes on and off.
POSSIBLE CAUSE
User defined status code is displayed by switch closure or
motor brush sensor closure to negative.
See OEM instruction manual for corrective action
required.
Other Causes:
Terminal 8 and 10 shorted to negative.
Defective input switch (shorted).
Defective TMM1 card.
NOTE: When SCR pump control is used with internal
TMM function, input terminal is PA4 and PA5 on pump
logic card.
STATUS INDICATION CRITERIA
This status code is displayed when the voltage at
terminal 8 and 10 of TMM is at zero volts.
Содержание EV100 LX
Страница 3: ...3 EV100LX COMPONENT LOCATIONS ...
Страница 4: ...4 EV100LX OUTLINE DRAWING ...
Страница 5: ...5 EV100LX WITH SPEED LIMIT AND FW 9 ...
Страница 6: ...6 EV100LX WITH REGEN AND FW 9 ...
Страница 7: ...7 EV100LX DUAL MOTOR CONTROL 9 ...
Страница 8: ...8 EV100LX PUMP CONTROL 9 ...
Страница 10: ...10 EV100LX PART NUMBER IDENTIFICATION ...
Страница 60: ...6 0 ...
Страница 80: ...g GE Industrial Systems EV200LX SUPPLEMENT Page 4 of 5 REV 11 2002 Wiring Diagram ...