STATUS CODE
-70
D E S C R I P T I O N
Regen current sensor input missing ( yellow wire ).
Yes
MEMORY
R E C A L L
C O N T R O L
T Y P E
Traction
Figure 1
STATUS INDICATION CRITERIA
This status code is displayed when input signal at PA4
is missing.
SYMPTOM
Control does not operate.
POSSIBLE CAUSE
Defective regen sensor input circuit.
Check yellow sensor wire for open circuit or loose
connection between sensor (welded connection) and
PA4.
STATUS CODE
-71
D E S C R I P T I O N
Regen current sensor input missing ( green wire ).
Yes
MEMORY
R E C A L L
C O N T R O L
T Y P E
Traction
Figure 1
STATUS INDICATION CRITERIA
This status code is displayed when input signal at PA5
is missing.
SYMPTOM
Control does not operate.
POSSIBLE CAUSE
Defective regen sensor input circuit.
Check green sensor wire for open circuit or loose
connection between sensor (welded connection) and
PA5.