5 8
STATUS CODE
-151
D E S C R I P T I O N
No
MEMORY
R E C A L L
C O N T R O L
T Y P E
Pump
Figure 1
STATUS INDICATION CRITERIA
This status code is displayed when capacitor volts
exceed 225 volts and motor current is greater than 300
amps.
SYMPTOM
Pump contactors open and close, then can only be closed
by opening and closing the key switch.
POSSIBLE CAUSE
Excessive source inductance.
Tag lines without filters are being used.
Battery cables are too long.
High peak current in motor.
Check for shorted field winding.
Check for shorted armature winding.
Excessive capacitor voltage when motor current is high.
STATUS CODE
-152
D E S C R I P T I O N
Excessive capacitor voltage when motor current is low.
Yes
MEMORY
R E C A L L
C O N T R O L
T Y P E
Pump
Figure 1
STATUS INDICATION CRITERIA
This status code is displayed when capacitor volts
exceed 225 volts and motor current is less than 200
amps.
SYMPTOM
Pump contactors open and close, then can only be closed
by opening and closing the key switch.
POSSIBLE CAUSE
Excessive source inductance.
Tag lines without filters are being used.
Battery cables are too long.
Defective 4 REC circuit.
Check for shorted 4 REC.
Check for open circuit or loose connection in 4
R E C
circuit.
Defective 3 REC circuit.
Check for open circuit or loose connection in 3
R E C
circuit.
Содержание EV100 LX
Страница 3: ...3 EV100LX COMPONENT LOCATIONS ...
Страница 4: ...4 EV100LX OUTLINE DRAWING ...
Страница 5: ...5 EV100LX WITH SPEED LIMIT AND FW 9 ...
Страница 6: ...6 EV100LX WITH REGEN AND FW 9 ...
Страница 7: ...7 EV100LX DUAL MOTOR CONTROL 9 ...
Страница 8: ...8 EV100LX PUMP CONTROL 9 ...
Страница 10: ...10 EV100LX PART NUMBER IDENTIFICATION ...
Страница 60: ...6 0 ...
Страница 80: ...g GE Industrial Systems EV200LX SUPPLEMENT Page 4 of 5 REV 11 2002 Wiring Diagram ...