3 3
STATUS CODE
-16
D E S C R I P T I O N
Battery volts too high.
No
MEMORY
R E C A L L
C O N T R O L
T Y P E
Traction
STATUS CODE
-15
D E S C R I P T I O N
Battery volts too low.
No
MEMORY
R E C A L L
C O N T R O L
T Y P E
STATUS INDICATION CRITERIA
Traction
Figure 1
Figure 1
SYMPTOM
Forward or reverse contactor will not pick up.
POSSIBLE CAUSE
Discharged battery
Check battery for proper open circuit voltage as
outlined in figure 1 and charge battery if required.
Defective battery
Check each battery cell for proper voltage (greater
than 1.95 volts at cell). Replace or repair battery.
Incorrect control card adjustment.
Check function 15 for proper adjustment for
battery
being used. See handset instruction
sheet for details. Adjust to proper settings.
This status code is displayed when the battery volts are
less than 1.95 volts per cell at initial start up. (See table
in figure 1).
SYMPTOM
Forward and reverse contactor will not pick up.
POSSIBLE CAUSE
Incorrect control card adjustment
Check function 15 for proper adjustment for battery
being used. See handset instructions for details.
Adjust to proper setting.
Battery over charged or incorrect battery used.
Check battery for proper open circuit voltage per
table in figure 1. If voltage excessive-check battery
charger for proper output voltage.
STATUS INDICATION CRITERIA
This status code is displayed when the battery volts
are greater than 2.40 volts per cell at initial start up.
(See table in figure 1.)
Содержание EV100 LX
Страница 3: ...3 EV100LX COMPONENT LOCATIONS ...
Страница 4: ...4 EV100LX OUTLINE DRAWING ...
Страница 5: ...5 EV100LX WITH SPEED LIMIT AND FW 9 ...
Страница 6: ...6 EV100LX WITH REGEN AND FW 9 ...
Страница 7: ...7 EV100LX DUAL MOTOR CONTROL 9 ...
Страница 8: ...8 EV100LX PUMP CONTROL 9 ...
Страница 10: ...10 EV100LX PART NUMBER IDENTIFICATION ...
Страница 60: ...6 0 ...
Страница 80: ...g GE Industrial Systems EV200LX SUPPLEMENT Page 4 of 5 REV 11 2002 Wiring Diagram ...