5 7
STATUS CODE
-149
D E S C R I P T I O N
No
MEMORY
R E C A L L
C O N T R O L
T Y P E
Pump
Figure 1
SYMPTOM
Pump contactor will open and close, then open and then
can only be closed by opening and closing the key
switch.
POSSIBLE CAUSE
Defective 5 REC circuit
Check for shorted 5 REC.
Check for shorted 5 REC snubber ( 25 REC ).
Check that 5 REC will gate on.
Check for open circuit or loose connection
between 5 REC gate and PZ12 ( white/violet wire
).
Shorted 2 REC circuit.
Check 2 REC and 2 REC snubber ( 22 REC ) for
short circuit.
Defective capacitor circuit.
Check for open capacitor.
Check for loose connections at capacitor terminals.
STATUS INDICATION CRITERIA
This status code is displayed when the 5 REC circuit
fails to turn on.
5 REC does not turn on properly
STATUS CODE
-150
D E S C R I P T I O N
No
MEMORY
R E C A L L
C O N T R O L
T Y P E
Pump
Figure 1
SYMPTOM
Pump contactor picks up. Control does not operate.
POSSIBLE CAUSE
Defective 2 REC circuit.
Open circuit or loose connection between spider
assembly and 5 REC (BUS A).
Open circuit or loose connection between 5 REC
and
2 REC.
Open circuit or loose connection between 2 REC
and PZ11 (red wire) and between 2 REC gate and
PZ10
(white/red wire).
Check 2 REC to insure that it will gate on.
STATUS INDICATION CRITERIA
This status code is displayed when 2 REC circuit fails
to turn on at initial start up.
Capacitor volts low .
Содержание EV100 LX
Страница 3: ...3 EV100LX COMPONENT LOCATIONS ...
Страница 4: ...4 EV100LX OUTLINE DRAWING ...
Страница 5: ...5 EV100LX WITH SPEED LIMIT AND FW 9 ...
Страница 6: ...6 EV100LX WITH REGEN AND FW 9 ...
Страница 7: ...7 EV100LX DUAL MOTOR CONTROL 9 ...
Страница 8: ...8 EV100LX PUMP CONTROL 9 ...
Страница 10: ...10 EV100LX PART NUMBER IDENTIFICATION ...
Страница 60: ...6 0 ...
Страница 80: ...g GE Industrial Systems EV200LX SUPPLEMENT Page 4 of 5 REV 11 2002 Wiring Diagram ...