3 7
STATUS CODE
-43
D E S C R I P T I O N
No
MEMORY
R E C A L L
C O N T R O L
T Y P E
Traction
STATUS CODE
-42
D E S C R I P T I O N
Control motor current sensor input missing.
No
MEMORY
R E C A L L
C O N T R O L
T Y P E
Traction
Figure 1
Figure 1
SYMPTOM
No power to traction motor in SCR range.
POSSIBLE CAUSE
Open sensor wire circuit to PZ4.
Check for loose connection or broken wire (green
wire) from current sensor to PZ4 on the logic card.
STATUS INDICATION CRITERIA
This status code is displayed when voltage between
PY7 and negative is greater than 1.6 volts with no
current flowing in the motor circuit.
Control motor current sensor input missing.
STATUS INDICATION CRITERIA
This status code is displayed when voltage between
PY7 and negative is less than .84 volts with no
current flowing in motor circuit.
SYMPTOM
Stall currents in SCR range higher than normal and
uncontrollable with C/L adjustment.
POSSIBLE CAUSE
Open sensor wire circuit to PZ3.
Check for loose connections or broken wire (yellow
wire) from current sensor to PZ3 on logic card.