72
DVSR xU User Manual
To set the RS-485 settings
1. In the PTZ menu set up the Baud Rate, Data Bits, Stop Bits, Parity, and Flow Ctrl. For each one in
turn, select the required configuration as provided by the dome manufacturer. For example, the
configuration for GE Security is: (default)
Baud rate – 9600
Data bits – 8
Stop bit – 1
Parity – None
Flow Crtl - None
To set the PTZ protocol
1. In the PTZ menu go to the
Protocol
list box and select one of the built-in PTZ protocols listed. See
Table 20.
Table 20 Built-in PTZ protocols
GE RS-485 (default)
LG
VideoTec Infinova
VCL SpeedDome
HIKVISION
Techwin DM
DynaColor
EVI-D30 DennardDome
Samsung DeltaDome
Siemens BBV
Philips 3
Tyco AD
Philips 2
AD
Philips Pelco
D
Panasonic Pelco
P
To set the PTZ address
1. In
the
PTZ Addr.
box enter a number for your PTZ address. If using the front panel or remote
control, press EDIT to delete a preceding number and Enter to confirm the entry. If using the
mouse, an onscreen numeric keypad appears.
To set camera preset positions
The preset position is the function to program monitoring positions (preset positions) associated with
position numbers. By entering the position number, you can move cameras automatically to the
preset positions. You can set up to 128 preset numbers. A preset number must have three digits. This
option is only available with cameras provided with the preset feature.
Содержание DVSR xU
Страница 1: ...GE Security P N DVSR xU_EN REV2 23 ISS 04MAR09 DVSR xU User manual ...
Страница 101: ...DVSR xU User Manual 97 ...
Страница 102: ......
Страница 103: ...DVSR xU User Manual 99 ...
Страница 104: ...DVSR xU Menu Map See page 30 See page 36 See page 49 See page 56 See page 63 See page 69 See page 76 See page 82 ...