Revision C
DINAMAP
®
ProCare
Monitor Service Manual
A-5
2009381-001
Technical Specifications:
Specifications
All DINAMAP
®
Monitor regulatory and accuracy studies have been performed
using CRITIKON
®
Blood Pressure Cuffs. Use only CRITIKON
®
Blood Pressure
Cuffs. The size, shape, and bladder characteristics can affect the
performance of the instrument. Inaccurate readings may occur unless
CRITIKON
®
Blood Pressure Cuffs are used.
Critikon US Patents
4,360,029; 4,501,280; 4,546,775; 4,638,810; 5,052,397; 4,349,034; 4,543,962;
4,627,440; 4,754,761; 5,170,795
European Patents
EP122123, EP205805, EP207807
Nellcor SpO
2
Measurement Range
SpO
2
1 to 100%
Pulse Rate
20 to 250 beats/min
Accuracy and Motion Tolerance
Saturation
Adults*
70 to 100% ±2 digits
Neonate*
70 to 100% ±3 digits
Low Perfusion**
70 to 100% ±2 digits
0 to 69% unspecified
Pulse Rate
Adult and Neonate
20 to 250 beats/min ±3 digits
Low Perfusion**
20 to 250 beats/min ±3 digits
*Adult specifications are shown for OxiMax
®
MAX-A and MAX-N sensors with the N-600. Neonate
specifications are shown for OxiMax
®
MAX-N with the N-600. Saturation accuracy will vary by sensor
type.
Содержание DINAMAP ProCare
Страница 2: ......
Страница 11: ...Revision C DINAMAP ProCare Monitor Service Manual 1 1 2009381 001 1 Introduction ...
Страница 12: ...1 2 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 For your notes ...
Страница 23: ...Revision C DINAMAP ProCare Monitor Service Manual 2 1 2009381 001 2 Equipment Overview ...
Страница 24: ...2 2 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 For your notes ...
Страница 38: ...2 16 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 Equipment Overview Functional Description ...
Страница 39: ...Revision C DINAMAP ProCare Patient Monitor Service Manual 3 1 2009381 001 3 Installation ...
Страница 40: ...3 2 DINAMAP ProCare Patient Monitor Service Manual Revision C 2009381 001 For your notes ...
Страница 53: ...Revision C DINAMAP ProCare Monitor Service Manual 4 1 2009381 001 4 Maintenance ...
Страница 54: ...4 2 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 For your notes ...
Страница 71: ...Revision C DINAMAP ProCare Monitor Service Manual 5 1 2009381 001 5 Troubleshooting ...
Страница 72: ...5 2 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 For your notes ...
Страница 76: ...5 6 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 Troubleshooting Alarm Code Interpretation ...
Страница 77: ...Revision C DINAMAP ProCare Monitor Service Manual 6 1 2009381 001 6 Parts List Drawings and Replacement ...
Страница 78: ...6 2 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 For your notes ...
Страница 99: ...Revsion C DINAMAP ProCare Monitor Service Manual A 1 2009381 001 A Technical Specifications ...
Страница 100: ...A 2 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 For your notes ...
Страница 108: ...A 10 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 Technical Specifications Specifications ...
Страница 109: ...Revision C DINAMAP ProCare Monitor Service Manual B 1 2009381 001 B Appropriate Use of NIBP Simulators ...
Страница 110: ...B 2 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 Appropriate Use of NIBP Simulators For your notes ...
Страница 115: ...Revision C DINAMAP ProCare Monitor Service Manual C 1 2009381 001 C Electromagnetic Compatibility EMC ...
Страница 116: ...C 2 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 Electromagnetic Compatibility EMC For your notes ...
Страница 133: ......