Optional Enclosures
B-9
March 2008
Circuit Board Installation
(cont.)
5.
Install the
RS232
,
ANALOG OUT
and
TRANSDUCER
connectors onto
the printed circuit board at the locations indicated in Figure B-2 on
page B-11. Make sure the marked pin #1 sides of the connectors
face the right side (keypad side) of the enclosure.
Note:
If any leads have come loose from the screw terminals on
these connectors, refer to Appendix C,
Optional Enclosures
, of
the
Startup Guide
for wiring instructions.
6.
Reconnect the main
POWER LEADS
to the screw terminals at the
rear of the printed circuit board. When properly installed, the lead
colors should be green, white and black, from left to right (as
viewed from the front of the enclosure).
7.
Reinstall all option cards, as described earlier in this chapter.
Insert all external option card connectors at the rear panel of the
meter.
8.
After checking for any loose hardware that may have fallen into
the enclosure, reinstall the top panel on the meter and secure the
panel in place with the four screws previously removed.
The Model DF868 flowmeter may now be placed back into service.
Reconnect the main power and refer to Chapter 2,
Initial Setup
, of the
Startup Guide
and Chapter 1,
Calibration
, of this
Service Manual
for
instructions on properly setting up the meter for accurate flow rate
measurements.
Note:
Be sure to record the printed circuit board replacement in
Appendix A,
Service Record
.
Содержание DigitalFlow DF968
Страница 2: ......
Страница 7: ...Chapter 1 ...
Страница 23: ...Chapter 2 ...
Страница 32: ...Chapter 3 ...
Страница 42: ...Chapter 4 ...
Страница 55: ...Appendix A ...
Страница 56: ...Service Record Introduction A 1 Data Entry A 1 ...
Страница 58: ...March 2008 A 2 Service Record Table A 1 Service Record Continued Date Description of Service Performed By ...
Страница 60: ...Appendix B ...
Страница 72: ...March 2008 Optional Enclosures B 11 Figure B 2 Model DF868 Rack Mount Console Assembly ref dwg 705 849 ...