GE Energy
D20/D200
Installation and Operations Guide
General 994-0078-2.00-7
Full
27
Familiarization
, continued
Standard
Power Supplies
The following table gives details of the standard chassis-mounted, auxiliary and
redundant power supplies that are available. Other power supplies are available for
specific requirements. Contact GE Energy for details.
Type
Part Number
Input
Output
Mounting
Chassis-
mounted
580-2004
20 – 60 VDC
+5 V, 7 A
+12 V, 2 A
-12 V, 1 A
24 VDC, 3 A
Chassis-
mounted
580-2005
20 – 60 VDC
+5 V, 7 A
+12 V, 2 A
-12 V, 1 A
48 VDC, 1.5 A
Chassis-
mounted
580-2006
100 – 300 VDC
or
85 – 264 VAC
+5 V, 7 A
+12 V, 2 A
-12 V, 1 A
24 VDC, 3 A
Chassis-
mounted
580-2007
100 – 300 VDC
or
+85 – 264 VAC
+5 V, 7 A
+12 V, 2 A
-12 V, 1 A
48 VDC, 1.5 A
Auxiliary
521 - 0103
20 – 60 VDC
24 VDC, 75 W
Rack-mounted
Auxiliary
521 - 0104
100 – 300 VDC
24 VDC, 75 W
Rack-mounted
Auxiliary
521 - 0105
90 – 250 VAC
24 VDC, 75 W
Rack-mounted
Auxiliary
521 - 0106
100 – 350 VDC
48 VDC, 120 W
Rack-mounted
Auxiliary
521 - 0107
90 – 250 VAC
48 VDC, 120 W
Rack-mounted
Redundant
580 - 0719
110 VAC/125
VDC
24 VDC
Redundant
580 - 0741
220 VAC/48
VDC
48VDC
Redundant
580 - 0789
110 VAC/ 48
VDC
48 VDC
Redundant
510 - 0241
115 VAC + 15%
30 – 60 VDC
48 VDC, 2.5 A
Rack-mounted
Redundant
510 - 0242
115 VAC + 15%
40 – 144 VDC
48 VDC, 2.5 A
Rack-mounted
D20/D200
Overcurrent
Protection
Make sure your D20/D200 power input is externally protected for overcurrent. The
fuse rating that is required depends on the specific power consumption of your
system.
Содержание D20