Chapter 3: Programming
Concord 4 Installation Manual
51
Low level reports
Shortcut: 01032, 01042,
01052, 01062, and
01072
Default: Off
This setting determines whether the following nonalarm conditions report to
a pager:
• Force armed
• Hardwired zone trouble (open or short)
• Supervisory (wireless devices)
• Low battery (wireless devices)
• Phone test
• Other nonalarm related conditions
Exception reports
Shortcut: 01033, 01043,
01053, 01063, and
01073
Default: Off
This setting determines whether the panel reports to a pager if the system is
not armed or disarmed at the specified schedule times, if open/close reports
are turned on.
Open/close reports
Shortcut: 01034, 01044,
01054, 01064, and
01074
Default: Off
This setting determines whether opening and closing reports are sent to a
pager. When turned on, the panel sends a closing report when the system
arms and an opening report when the system is disarms.
To use this feature, the opening reports and closing reports settings under
the “Reporting menu” on page 59 must be turned on for that partition.
Latchkey reports
Shortcut: 01035, 01045,
01055, 01065, and
01075
Default: On
This setting determines whether the panel reports to a pager when the
system arms or disarms, according to latchkey time scheduling.
Streamlining
Shortcut: 01036, 01046,
01056, 01066, and
01076
Default: On
This setting determines whether the panel includes (off) or excludes (on) the
account number when reporting to a pager.
Partition assignment
Shortcut: 01037, 01047,
01057, 01067, and
01077
Default: 1
This setting determines the partition that reports to a pager. All partitions
may be set to report to a single pager.