Chapter 3: Programming
Concord 4 Installation Manual
59
Reporting menu
Reporting - global settings
24-hour tamper
Shortcut: 06000
Default: Off
When this setting is turned on, the panel sounds sirens and reports a
tamper alarm (even when the system is disarmed), when nonfire wireless
sensor tamper switches are activated.
When this setting is turned off, the panel sounds sirens and reports a
tamper alarm only when nonfire wireless sensor tamper switches are
activated and those sensors are active for the current arming level. For
nonfire sensors not active in the current arming level that have their
tamper switch activated, trouble beeps sound and the panel sends a
sensor tamper report to the central station if the system tamper feature is
on for that partition.
Tamper conditions for fire sensors (group 26) always cause trouble beeps
to sound and report the tamper condition to the central station,
regardless of this feature setting.
Antenna tamper
Shortcut: 06001
Default: Off
This setting determines whether the panel monitors for antenna tamper
of onboard and all connected bus transceivers and receivers. When
turned on, the panel sounds trouble beeps in all partitions and reports an
antenna tamper condition. Touchpads in all partitions show a receiver
tamper trouble condition. When turned off, the panel ignores antenna
tampers.
Buffer control
Shortcut: 06002
Default: Off
When this setting is on, only arming level changes and time changes
(system time and daylight saving time) are logged in the buffer (memory)
of the panel. When this setting is off, all system events are logged in the
buffer.
Back in service
Shortcut: 06003
Default: On
When this setting is on, the panel reports to the central station when AC
and backup battery power are restored (after an extended power outage).
Bypass reports
Shortcut: 06004
Default: Off
When this setting is on, the panel reports to the central station whenever
sensors or zones are bypassed.
Low CPU battery
Shortcut: 06005
Default: On
When this setting is on, the panel reports a low panel battery to the
central station when the system battery test fails. If this setting and the
Aux power fail feature are both on, the panel also monitors for and
reports a low battery for the SuperBus 2000 2-amp power supply.
Battery restoral
Shortcut: 06006
Default: Off
If this setting is on, the panel reports to the central monitoring station
when a wireless sensor or touchpad reports a battery replacement to the
panel.
Buffer full report
When this setting is on, the panel sends an event buffer full
report to the
central monitoring station when the event buffer is nearing full. When