Chapter 3: Programming
Concord 4 Installation Manual
37
Clear memory
Clearing memory deletes all existing programming information (except the
dealer code).
Note:
Clearing the memory erases onboard hardwired zone factory
programming.
To clear panel memory:
1. With the system in program mode, press A
or B
until the display shows
CLEAR MEMORY.
2. Press #. The display shows
ENTER CODE TO CLEAR MEMORY.
3. Enter the four-digit installer or dealer code (if programmed) and press #.
After about 5 seconds, the system restarts and the panel scans the bus to
learn all bus devices. If the system doesn’t respond as shown, repeat the
process.
Exiting programming
After all installer/dealer programming is completed, exit programming mode.
To exit programming mode:
1. Press *
until the display shows
SYSTEM PROGRAMMING.
2. Press A
or B
until the display shows
EXIT PROGRAMMING READY.
3. Press #. The touchpad displays the time and date
.
Tier 2 programming menus
Table 10 below shows the tier 2 system programming menus. Where applicable, the
setting name is followed by the (shortcut) and [default].
Table 11: System programming menus
Security Global
Downloader code (0000) [12345]
Installer code (0001) [4321]
Dealer code (0002) [****]
Access code lock (0003) [On]
Ptn security (0004) [On]
Multi ptn arm (0005) [None]
Keychain tp ptn (0006)
Partition
Account number (0010 to 0060) [00000]
Quick arm (0011 to 0061) [Off]
Quick exit (0012 to 0062) [Off]
Exit extension (0013 to 0063) [On]
Keyswitch sensor (0014 to 0064) [None]
Keyswitch style (0015 to 0065) [Transition]
Duress code (0016 to 0066) [****]
Содержание Concord 4
Страница 1: ...GE Security P N 466 2182 REV G ISS 12JUL10 Concord 4 Installation Manual ...
Страница 6: ...iv Concord 4 Installation Manual ...
Страница 96: ......