Chapter 3: Programming
Concord 4 Installation Manual
61
Flow battery report
Shortcut: 06013
Default: Weekly
This setting determines whether the panel sends daily (1) or weekly (2) low
battery reports to the central monitoring station when a wireless device is
reporting a low battery condition to the panel.
RF low battery report
Shortcut: 06013
Default: Weekly
This setting determines whether the panel sends daily (1) or weekly (2) low
battery reports to the central monitoring station when a wireless device is
reporting a low battery condition to the panel.
RF supervisory report
Shortcut: 06014
Default: Weekly
This setting determines whether the panel sends daily (1) or weekly (2)
reports to the central monitoring station when the panel detects a
supervisory condition in a wireless device.
Swinger limit
Shortcut: 06015
Default: 1
This setting determines the maximum number of times (1 or 2) a sensor or
zone can go into alarm (during a single arming period) before the panel
automatically bypasses that sensor or zone. This feature only applies to
sensors or zones in groups 00–20, 29, 34, 35, or 38.
When set to 1, the panel automatically bypasses a sensor or zone after it
causes an alarm. When set to 2, the panel waits until a sensor or zone has
caused a second alarm (during the same arming period) before bypassing
it. At any setting, the automatic bypass is logged into the event buffer.
A bypassed sensor or zone will be cleared (automatically unbypassed) if
the system receives no further activations from that sensor or zone over
the next 48 to 50 hours.
Changing the arming level also clears all automatically bypassed sensors
and zones and resets the swinger limit count on all sensors and zones.
Auxiliary power failure
Shortcut: 06015
Default: On
When this setting is on, the panel sends a report to the central monitoring
station if the 12 VDC power outputs on the panel and/or SuperBus 2000
2-amp power supply fail.
If this feature is on and the AC failure and low CPU battery features are
both on, the panel sends AC failure and low backup battery reports for the
SuperBus 2000 2-amp power supply.
Ground fault
Shortcut: 06017
Default: On
When this setting is on, the panel will annunciate and send a report to the
central monitoring station if it detects current flow between the panel’s
circuitry and the chassis. This indicates that a short to earth ground exists
somewhere in the system.
This feature must be on if hardwired smoke sensors are used in this
system.
Содержание Concord 4
Страница 1: ...GE Security P N 466 2182 REV G ISS 12JUL10 Concord 4 Installation Manual ...
Страница 6: ...iv Concord 4 Installation Manual ...
Страница 96: ......