Chapter 4: Testing and troubleshooting
Concord 4 Installation Manual
93
Command System
response
* (STATUS)
Indicates current system status
7, 1
Turns chime feature on and off
7, 2
Turns energy saver on and off
7, 4
Partition jump without entering code (only if partition
security option is off)
7, 6
Identifies alarms in memory
7, 7, n (n = output number [1to6])
1 to 2 = onboard outputs;
3 to 6 = module outputs
Turns the output on or off. (This command is only functional
after output text is entered into panel memory.)
8,
code
, 2
Initiates a phone test
8,
cod
e, 3
Initiates a sensor test
8,
installer code
, 3
Initiates a dealer sensor test
8,
code
, 6
Partition jump
8,
code
, 8
View event history
0, 0
Turns all controlled lights on and off
0, n (n = light number 1 to 9)
Turns individual controlled light on and off
Zones/sensors
Test sensors/zones after all programming is completed; whenever there is a change
in environment, equipment, or programming; and whenever a zone- or sensor-
related problem occurs.
If the system does not respond as described in the following procedure, see
Troubleshooting.
Note:
While the sensor test is a valuable installation and service tool, it only tests
sensor operation for the current conditions. You should perform a sensor test after
any change in environment, equipment, or programming.
To test zones/sensors:
1. Place all sensors and zones in their nonalarm state.
2. At an alphanumeric touchpad, enter the sensor test mode by pressing 8,
installer
code
, 3. The touchpad sounds one beep and displays
SENSOR TEST
. The panel
starts a 15-minute timer.
3. Trip each zone/sensor one at a time. Touchpads (and interior sirens) should sound
one short, high-pitched beep, and the display should show the sensor name (or
number) and OK.