Chapter 3: Programming
Concord 4 Installation Manual
49
Phones - central station phone 1 to 3 settings
Phone number
Shortcut: 01000, 01010,
and 01020
Default: None
Use this setting to program the central station receiver phone number.
Phone numbers can be 1 to 24 digits long, including pauses or *and #
characters.
The phone menus are not accessible if a dealer code is programmed and
the installer code is used to enter installer programming mode. To access
these menus when a dealer code is programmed, you must enter installer
programming mode using the dealer code. Call-waiting services should be
disabled to prevent interrupting panel communication to the central
monitoring station. To program a dialing prefix that disables call waiting,
see the call wait cancel setting under the menu “Phone options - global
settings” on page 52.
To delete a central station phone number, with the display showing
PHONE
NUMBER
(current number), press D. The display shows
PHONE NUMBER
_.
High level reports
Shortcut: 01001, 01011,
and 01021
Default: On (1),
Off (2 and 3)
When this setting is on, the following conditions report to the central station:
• Fire, police, auxiliary, and duress alarms
• No activity
• Receiver failure (or jam)
• Tamper conditions, including zone tampers and system tamper (40
incorrect key presses or touchpad supervisory)
• Entering or exiting sensor test mode
• Phone test
Low level reports
Shortcut: 01002, 01012,
and 01022
Default: On (1),
Off (2 and 3)
When this setting is on, the following nonalarm conditions report to the
central station:
• Force armed
• Hardwired zone trouble (open or short)
• Supervisory (wireless devices)
• Low battery (wireless devices)
• Phone test
• Other nonalarm related conditions
Exception reports
Shortcut: 01003, 01013,
and 01023
Default: Off
When this setting is on, the panel reports to the central station if the system
is not armed or disarmed at the specified schedule times.
Open/close reports
Shortcut: 01004, 01014,
and 01024
Default: Off
This setting determines whether opening and closing reports are sent to the
central station. When turned on, the panel sends a closing report when the
system is armed and an opening report when the system is disarmed.
To use this feature, the opening reports and closing reports settings under
the “Reporting menu” on page 59 must be turned on for that partition.