T he u pper m ain roller and the up per pull
roller should b e in the raised position.
IN F O R M A T IO N
c) Set the air in pressure from the source to 100
pounds per square inch (psi) (700 kPa).
R elease m oistu re from the air filter on a
w eek ly basis or as needed.
IN F O R M A T IO N
d) Press up on the pin located at the very bottom of
the air filter to release moisture in the trap.
P res s h ere
4.9 Installing levelers
Leveling of the machine is a customer option. If
you choose not to level the laminator and you encounter
output problems, please level the machine and try your
application again before calling for technical support.
Resting the laminator on the leveling pads will prevent the
machine from rolling during set up, operation or servicing.
Tools required
• ( 1 ) 1/2 in. open end wrench
• ( 1 ) 7/8 in. open end wrench
• (4) leveling pads
( from the accessory pack )
a) Be sure that the machine is placed where you
want it to rest.
b) Secure the four leveling pads onto the four foot
bolts.
c) Use the 1/2 in. wrench on the foot bolt and the
7/8 in. wrench on the leveling pads and tighten
them together.
1 /2 in . w re n c h
7 /8 in . w re n c h