( 27 ) SAFETY : Begins flashing anytime the front or
the rear safety shield is in the raised position. This is an
indication for the operator to be very careful when
operating the laminator in the “Footswitch” mode.
27
F W R
R E V .
S T O P
G O
S P E E D
S A F E T Y
6.5
( 28 ) Variable Speed Footswitch : The variable
speed footswitch, operates the laminator in
“Footswitch” mode. Within this mode, if the safety
shield is up, speed is determined by the variable speed
footswitch. If the safety shield is down, the speed is
controlled through the control panel.
ATTUNG
WARNING
ADVERTENCIA
28
Panel to Footswitch
1. To switch from “Panel” mode ( GO is solid ) to
“Footswitch” mode ( GO is flashing ) with the safety
shields in the down position. Perform the following
steps;
• Press on the variable speed footswitch. GO
begins flashing identifying “Footswitch” mode.
• Once the variable speed footswitch is released,
the rollers will stop.
• To make the rollers turn, simply press on the
variable speed footswitch.
INFORMATION
When the safety shield is in the lowered
position and "Footswitch" mode is
engaged, speed is controlled through
the control panel
Footswitch to Panel
2. To switch from “Footswitch” mode ( GO is flashing )
to “Panel” mode ( GO is solid ) with the safety
shields in the down position. Perform the following
steps;