9/5/2007
19
Troubleshooting Guide
All equipment is tested for proper performance before it is shipped from the factory.
However, if you experience any difficulties, check the list below to help restore
equipment to proper operating standards.
PROBLEM
CORRECTION
•
Pump motor will not start.
•
Check electrical connections.
•
Touch Screen freeze during
start up.
•
Turn off the crimper for 5
minutes then return and try
again. If the problem persists,
call Gates Product Application
•
Will not hold crimp calibration.
•
Flange head bolts are loose.
Check torque of flange bolts to
215 Nm or 1903 in lbf every 6
months of operation.
Schematic and Replacement Parts List
GC32 Die Set Available
Die Set
Product
Number
Part
Number
Notes
32-21
7482-7025
Requires 96 Spacer
32-22
7482-7026
Requires 96 Spacer
32-31
7482-7027
Requires 96 Spacer
32-33
7482-7028
Requires 96 Spacer
32-34
7482-7029
Requires 96 Spacer
32-35
7482-7030
Requires 96 Spacer
32-36
7482-7031
Requires 96 Spacer
32-37
7482-7032
Requires 96 Spacer
32-38
7482-7033
Requires 96 Spacer
32-39
7482-7034
Requires 96 Spacer
32-310L
7482-7035
Requires 96 Spacer
32-311
7482-7036
Requires 96 Spacer
32-312
7482-7037
Requires 96 Spacer
32-313
7482-7038
Requires 96 Spacer
32-314
7482-7039
Requires 96 Spacer
32-40
7482-7040
Air Conditioning
32-41
7482-7041
Air Conditioning
32-42
7482-7042
Air Conditioning
32-43
7482-7043
Air Conditioning
32-44
7482-7044
Power Steering
32-45
7482-7045
Grease
32-46
7482-7046
Battery Cable
Содержание GC96