9/5/2007
13
Options Screen
The OPTIONS SCREEN allows the
operator to press TOOLS and perform die
changing with the GC32 Quick Change
Tool and also to perform Field Calibrations
with the Offset button.
DIE CNG – Holding this button will automatically
select head direction and move the head to a
position more suitable for Standard GC32 Die
Changes. It may be necessary to press the
button twice to get it into the die change position.
OFFSET– Allows the operator to input
a value of 0 to 500 to perform a field
calibration on the GC96 crimper.
When the OFFSET button is pressed, a
keypad is revealed and a value may be
input and ENTERED and will cause the
crimp OD to be larger or smaller for a
given setting. See calibration section
for further details.
NOTE- If the ENTER key is not
pressed, the new offset value will
not be loaded!
CAL – Allows access to Factory
Calibration and is not necessary for normal
operation of the GC96 crimper. Strictly
ONLY for USE by qualified Gates
Maintenance Engineers.
Содержание GC96