9/5/2007
1
GC96 Operators Manual
Crimper Specifications
Prod. No.: 7480-9001
Power source
:
Any world-wide 210-257 VAC, 20 Amps, 45 to 65 Hz electrical source
Dimensions: 37” H x 23” W x 19 ½” D
Approx. Weight: 804 lbs.
Maximum Rated Working Pressure: 4350 PSI (300 bar)
Carefully read and understand the following warnings before operating this crimper.
WARNING!
An incorrect hose assembly can rupture or blow apart in use, resulting in serious injury,
death, or property damage. REMEMBER: Others depend on you to make correct
assemblies.
FOR SAFETY’S SAKE
USE THIS MACHINE ONLY IF YOU:
1. Receive hands-on TRAINING with this Gates crimper and assemblies.
2. Follow current GATES OPERATING MANUAL and CRIMP DATA for the GC96
crimper.
3. Wear SAFETY GLASSES.
4. Keep hands clear of moving parts.
NOTE ON OPERATING TEMPERATURE:
The GC96 crimper has been designed to operate in a 32
°
F to 122
°
F (0C to 50C)
ambient temperature range and stored in a -4
°F to 122°F (-20C to 50C) ambient
temperature range
. It is also important that the crimper should be acclimated after
delivery in its work facility for 24 hours prior to use. If the crimper isn’t acclimated or the
crimper is stored or operated outside the indicated temperature range it is possible that
there may be oil leakage at the kickers. Additionally, if the correct breather assembly
isn’t installed, oil droplets may form at the oil level sight glass, around the shipping cap/
breather assembly and at the reservoir deck plate. If either of these conditions occurs,
the operator should wipe off these surfaces and replace the shipping cap with the
breather assembly, if necessary. The crimper will then operate normally.