9/5/2007
8
▲
WARNING:
To prevent serious injury:
•
Keep away from all moving parts! If bodily contact should occur with a
moving part, immediately release CRIMP button or foot pedal.
•
Do not operate crimper with hand, fingers, or any body part in crimper
mouth. Serious injury can occur.
•
Keep additional personnel away from crimper while operating.
E. Remove piece and measure crimp diameter. Crimp diameter must measure
3.920" +/- .003".
F. If the crimp diameter is acceptable, no adjustment is necessary.
G. If crimp diameter is not acceptable, crimper must be calibrated. Proceed as
follows:
a. Press OPTIONS then TOOLS on the TOUCH SCREEN control panel.
Press OFFSET. Then press Open Keypad. Type in 4296 and press ENTER.
b. Use Calibration equation to determine approximate new setting.
Adjusted Setting = Factory Offset Value- [(Actual COD - Target COD) x 2200]
Changing the Offset Value by approximately 2 will change crimp diameter
0.001”. Changing the Offset Value by approximately 50 will change crimp
diameter approximately 0.025”.
c. Type in the Adjusted Setting and press ENTER.
NOTE- If the ENTER key is not pressed, the new offset value isn’t loaded and the
crimper will crimp to the previous set point!
H. Repeat calibration steps until published crimp diameter is achieved. Crimper is
now calibrated.
NOTE: CRIMP button and foot pedal operate on a “dead man” control. It only operates
as long as you depress the CRIMP button or hold foot pedal down. It stops immediately
when switch is released.