9/5/2007
4
2. Fill crimper with oil unless oil already filled (check sight glass on
front of reservoir)
Remove the shipping cap / breather assembly behind the crimper head. Fill the GC96
with 12 gallons (45 liters) of AW46 oil.
The GC96 crimper has been designed to operate in a 32
°
F to 122
°
F (0C to 50C)
ambient temperature range with AW46 oil.
NOTE- If the GC96 crimper has been stored below -4
°F ambient temperature,
the
crimper should be acclimated after delivery to its work facility for 24 hours prior to use. If
the crimper isn’t acclimated or the crimper is stored or operated outside the indicated
temperature range, 32
°
F to 122
°
F (0C to 50C) operating and -4
°F to 122°F (-20C to
50C) for storage,
it is possible that there may be oil leakage at the kickers.
Additionally, if the correct breather assembly isn’t installed, oil droplets may form at the
oil level sight glass, around the shipping cap/ breather assembly and at the reservoir
deck plate. If either of these conditions occurs, the operator should wipe off these
surfaces and replace the shipping cap with the breather assembly, if necessary. The
crimper will then operate normally.