13-17-618 Page 15
2-2
a source of adequate cooling air, or to direct cooling air in and out of the compressor package to prevent
re-circulation (e.g., not cooling the air entering the fresh air inlet). The package is designed to operate at
ambient temperatures ranging from 40
F to 113
F (at up to 1000 meter elevation). Contact your local
distributor for package operation at conditions exceeding the stipulated values.
A typical ventilation arrangement is shown in Figure 2-1.
Figure 2-1
– TYPICAL COMPRESSOR ROOM
When selecting the compressor package location, be aware that its noise level may increase above its
advertised free-field condition by reflections from nearby objects (e.g., walls, machinery, etc.) or by noise
from nearby machinery.
Air-Cooled Units
- A combination oil/air cooler is supplied as standard equipment on all air-cooled
packages. The heat exchangers require sufficient cooling air flow to operate efficiently
– please refer to
Section 6, Fig 6-1, page 53 of this manual for detailed instructions on the operation and maintenance of
air-cooled heat exchangers, including minimum heat exchanger cooling and enclosure ventilation
requirements.
Air for heat exchanger cooling is drawn in at the cooler end of the enclosure and is exhausted through a
roof vent. Air for motor cooling and for the compressor intake is drawn in at the controller end and
exhausted at a smaller roof vent. Refer to Package Illustrations on Figure 1-2 and Figure 1-3, pages 10
and 11, for hardware details.
Do not block flow of air entering or exiting the enclosure - allow 3-1/2 feet (1.1 m) clearance to the nearest
obstruction all around and on top.
Water-Cooled Units
– Separate shell-and-tube coolers for air and oil services are supplied on water-
cooled packages. The heat exchangers require sufficient cooling water flow to operate efficiently
– please
refer to Section 6 of this manual for detailed instructions on the operation and maintenance of water-
cooled heat exchangers, including minimum cooling water flow requirements.