13-17-618 Page 76
15-2
SYMPTOM
POSSIBLE CAUSE
REMEDY
Compressor
does not
unload (or
load)
1.
Improperly adjusted controller
1.
Refer to Manual 13-17-600 and
adjust control.
2.
Feed pressure regulator not
adjusted
2.
Inspect, adjust and replace
pressure regulator.
3.
Feed 3-way solenoid valve
malfunction
3.
Repair, clean or replace valve.
4.
Inlet valve stuck
4.
Inspect and replace valve.
5.
Blow down valve malfunction
5.
Repair, clean or replace valve.
Compressor
cycles from
load to unload
excessively
1.
Insufficient receiver capacity
1.
Increase receiver size
2.
Restriction in service piping
2.
Inspect and clean service piping.
3.
Restriction in control tubing
3.
Inspect and clean control tubing.
Compressor
starts too
slowly
1.
Acceleration time in VFD set too
long
1.
Contact your Gardner Denver
distributor.
2.
Minimum Pressure/Check Valve
is leaking
2.
Repair or replace.
Compressor is
low on delivery
and pressure
1.
Improperly adjusted control
1.
Refer to Manual 13-17-600 and
adjust control.
2.
Restricted air filter
2.
Clean or replace filter element.
3.
Inlet valve not fully open
3.
Inspect, adjust or replace feed
solenoid valve and/or pressure
regulator.
4.
Minimum pressure valve stuck
closed
4.
Inspect, service or replace valve.
5.
Air leaks in service piping
5.
Inspect or replace solenoid valve.
Ensure local ambient temp has not
exceeded 113
F. limit.