13-17-618 Page 22
3-2
Before removing the oil filler plug, always stop the unit and release air
pressure, lockout and tagout the power supply to the compressor package.
Failure to release pressure or properly disconnect the power may result in
personal injury or death.
2.
Air Filter
- Inspect the air filter to be sure it is clean and the assembly is sealed tight. Refer to
Section 7, page 55
“Air Filter”, for complete servicing instructions. Be sure the inlet line is clean and
sealed tight.
3.
Couplings
- Check set screws for tightness. See Section 8, page 57.
4.
Piping
- Refer to Section 2, page 14
“Installation,”
and make sure piping meets all
recommendations.
5.
Electrical
- Check the wiring diagrams furnished with the unit to be sure it is properly wired. See
Figure 4-3 thru Figure 4-11, pages 33 thru 41, for general wiring diagrams and Section 2, page 14
for installation instructions.
6.
Grounding
- Equipment must be properly grounded according to Gardner Denver Guidelines for
proper wiring, grounding and feed power conditioning.
Failure to properly ground the compressor package could result in controller
malfunction.
NOTICE
Read the Operator’s Manual before operating the compressor.
7.
Rotation
- Check for correct rotation of all electric motors:
Use controller “JOG MODE” to bump compressor motors. Proper rotation (either stage) shall be
counterclockwise when facing the compressor shaft end.
Start/Stop controller to bump heat exchanger cooling fan. Proper rotation shall be
counterclockwise when facing rear of fan drive motor.