The lubricating and cooling oil must be kept at a normal operating temperature below 225
F in order
to preserve its longevity.
The compressed air supply must be delivered into the distribution system at a temperature not
exceeding 15
F above the ambient level in order to protect other devices (e.g., filters, dryers, tools,
etc) against damage. At 100 psi of discharge pressure, the air core allows the flow of 668 cfm with
1.5 psid pressure loss.
AIR-COOLED HEAT EXCHANGERS
– Air-cooled cores (radiator-type) are provided as standard feature.
A radial fan, located on the discharge side of the heat exchanger core, draws in the required amount of
cooling air and expels it through an opening on the enclosure roof. The fan is driven by an inverter-duty,
TEFC- electric motor energized by a pulse-width-modulated variable frequency drive.
Refer to Figure 6-1 for estimates of ventilation requirements. Please note that the air-cooled package
requires the combined total of the heat exchanger plus the enclosure ventilation flow rates (which include
motor ventilation and compressor intake). Furthermore, when package location makes it necessary to
duct fresh cooling air in/out, these ducts must be sized with a maximum (total) pressure loss of 1/8 inch
water gauge to avoid impacting the heat exchanger cooling air system.
Minimum Cooling Air Flow Requirements
CFM
KW
Air-Cooled
Heat
Exchangers
Enclosure
Ventilation
Fan
55
9272
2000
75
11605
2000
90
13529
2000
Figure 6-1
– AIR FLOW CHART
All the required hardware, mechanical and electrical connections have been made at the Gardner Denver
factory, thus the only regular maintenance required is to keep the exterior core fins free from dirt and
other airborne debris per the following procedure:
Air-cooled heat exchanger cores are fabricated from aluminum. Do not use
caustic liquids to cleanse core or permanent damage will take place.
1. Be sure the unit is completely off and that oil reservoir is depressurized.
2. Disconnect, lockout and tagout power supply to the compressor package.
3. Open and/or remove enclosure door panels adjacent to cooler assembly.
4. Locate cooler housing side covers (See Figure 6-2) and remove by unscrewing fasteners.