Preparing for commissioning
5
January 2017
America
31 /72
The compressor system is completely finished
at the factory according to EN 60204 (Industrial
Machinery).
The power supply to the compressor must be
suitable for industrial equipment and must meet
all requirements of EN60204-1/IEC60204-1.
If the installation conditions deviate from the
conditions as described in EN 60204, consult
Gardner Denver.
Provide the electrical connection and protective
measures according to VDE, BS, or local
requirements. As a rule, additional regulations
from the corresponding power company must
also be complied with.
A main switch must be fitted on-site upstream
of the compressor (DIN EN 1012 - 1) insofar
that such a switch has not already been fitted
in the factory as a special accessory. The main
disconnect switch must meet the requirements
of the safety standard EN 60 204-1 (Electrical
Equipment for Machinery) and EN 60947-2
(Low Voltage Equipment).
The compressor must be protected by suitable
line fuses according to EN 60269-1 (Low
Voltage Directive).
If other electrical circuits are run to the
electronic controller afterward, such as lighting,
heating, or the like, that are not disconnected
by the main disconnect switch, then these
excepted electrical circuits must be labeled and
run separately per EN 60204. Warning labels
must also be installed near the main disconnect
switch and near these circuits.
Should an electrical connection to an
unearthed AC electrical circuit (IT network) be
made, observe the instructions in the supplied
documentation of the frequency converter (only
RS compressors).
Electrically connect the compressor
1
2
3
Fig. 5-2: Supply line openings
[1]
Compressed air connection
[2]
Condensate connection
[3]
Electrical connection
DANGER
Electric shock
Deadly electrical voltage
➯
Work on the electrical equipment
may be performed only by
authorized electrical technicians.
1
Remove the factory cover.
2
Install a customer supply line cover.
3
Run the supply lines through the openings in
the electrical enclosure.
4
Connect the supply lines; see wiring diagram.
5
Tighten the cable screws.
Check the setting of the fan circuit breaker.
DANGER
Electric shock
Deadly electrical voltage
➯
Work on the electrical equipment
may be performed only by
authorized electrical technicians.
1
Check the setting of the circuit breakers for the
two fan motors; see wiring diagram.
2
Set the circuit breakers for the correct grid
voltage and frequency; see wiring diagram.
Содержание L160 110A V2
Страница 1: ...User manual Screw compressor L160 L290 V2 L160RS L290RS V2 America ZS1149274 03 January 2017...
Страница 7: ...Foreword 1 January 2017 America 7 72 1 6 Rating plate Fig 1 1 Rating plate...
Страница 69: ...Appendix 9 January 2017 America 69 72...
Страница 70: ...9 Appendix 70 72 America January 2017...
Страница 71: ...Appendix 9 January 2017 America 71 72...