Maintenance and service
8
January 2017
America
55 /72
°
You must ensure that the triangular marks
on the drive housing are fully visible.
°
If these marks are not fully visible, release
the union nut and put the drive back on
again.
10
Insert plug in the drive and apply union nut
again so it is finger-tight.
11
Shut enclosure.
8.6.9
Control system
Test emergency stop button
[1]
Touchscreen Display
[2]
Start button < I >
[3]
Stop button < O >
[4]
red LED
flashing slowly: Warning or maintenance
flashing rapidly: Fault
[5]
yellow LED
flashing slowly: Maintenance necessary
[6]
green LED
lit up permanentaly: System in operation
flashing: Sytem in standby
[7]
Pushbutton <Emergency-stop>
NOTE
The emergency stop function may be actuated
only in dangerous situations. Otherwise
increased wear, up to and including damage to
the compressor, can be expected.
Test the emergency stop button only when the
compressor is stopped.
1
Press the stop button < O >.
– The status message of the electronic
controls is [
Ready to start
].
1
Press the <E-stop> button.
– The electronic controller displays the fault
message [
Emergency Stop Activated
].
– The "Fault memory" register card blinks.
2
Unlock the <E-stop> button.
Turn the button counterclockwise.
3
Reset fault message.
To do so, press the [
RESET
] button on the
“Fault memory” register card in the electronic
controller.
– The "Fault memory" register card stops
blinking.
8.6.10 Checking intervals for pressure
vessel and electrical installation
Pressure vessel
The checking intervals for the compressed-air
vessel and the safety valve have to be coordinated
with the local approval bodies.
Electrical installation
After four years, or after each instance of
interference, the electrical installation is to
be subjected to an inspection by an electrical
specialist.
If shorter checking intervals apply in your territory,
please adhere to them.
8.6.11 Maintenance instructions and
lubricant recommendations for
fixed compressors
Lubricant recommendation
Please note that proper lubrication significantly
increases the service life of your compressor
system.
In accordance with applicable accident prevention
regulations, lubrication oils whose properties meet
the intended operating conditions are to be used.
Please refrain from mixing different lubrication oils.
This also means oil must be completely drained
from the oil circuit when changing oil types.
The oil change intervals stated in the maintenance
plan are to be halved when final compression
temperatures are continuously higher than
90°C/195°F.
A precise specification of the oil change
intervals should be defined according to the
operating conditions that actually exist through oil
examinations.
The following types of oil are to be used:
USA version:
•
AEON9000SP
•
AEON9000TH (optional)
•
AEON6000FG-46 (optional)
•
AEON9000FG (optional)
•
For further information, please contact your
local CompAir Distributor or Gardner Denver-
USA at 866-440-6241.
Содержание L160 110A V2
Страница 1: ...User manual Screw compressor L160 L290 V2 L160RS L290RS V2 America ZS1149274 03 January 2017...
Страница 7: ...Foreword 1 January 2017 America 7 72 1 6 Rating plate Fig 1 1 Rating plate...
Страница 69: ...Appendix 9 January 2017 America 69 72...
Страница 70: ...9 Appendix 70 72 America January 2017...
Страница 71: ...Appendix 9 January 2017 America 71 72...