Clearing a fault
7
January 2017
America
41 /72
Fault
Potential root cause
Remedy
Lubrication system not dispens-
ing, despite voltage being sup-
plied. The plug icon appears on
the display.
Drive and LC not screwed
together properly.
Screw the drive and LC together
until the white triangle on the drive
is fully visible.
Lubrication system is in pressure
cut-off.
OL
Counter-pressure to
lubrication point > 87 psi.
•
Flush lubrication point
(manually or special dispensing
PURGE I)
•
Pressure check if necessary
•
Acknowledge fault by pressing
the SET key.
Lubricant cartridge empty, but no
“LC” message.
LC unit too small for the drive. Use the original LC unit MLS 120
of Gardner Denver.
Chart 7-7: Troubleshooting and clearing faults on the lubricator