![Gardner Denver L160 110A V2 Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/gardner-denver/l160-110a-v2/l160-110a-v2_user-manual_3807675042.webp)
7
Clearing a fault
42 / 72
America
January 2017
Fault
Potential root cause
Remedy
Message “LC” even though lubri-
cant cartridge is not completely
emptied.
LC
LC unit too big for the drive.
Use the original LC unit MLS 120
of Gardner Denver.
Display not working despite volt-
age being supplied.
Internal drive fault.
Replace entire lubrication system
“Lo” message on the display.
Lo
Weak backup battery of the drive. Change the CR2450 (3V) backup
battery.
May only be changed by trained
personnel.
“Er” message on the display.
Er
Internal drive fault
Replace entire lubrication system
Chart 7-7: Troubleshooting and clearing faults on the lubricator