13–8–612 Page 18
operating pressure. See “Programming the Load–Un-
load Pressure Setpoints,” page 19. The LED is illumi-
nated whenever the unit is stopped for any reason EX-
CEPT a normal stop in one of the “AUTO” modes. A
flashing LED indicates that a reset is required.
Damage will occur to the machine if it
is repeatedly restarted after any one
of the shutdown modes stops opera-
tion of the unit. Find and correct the
malfunction before resuming opera-
tion.
“CONSTANT RUN” Button With LED – This button
is used to operate the unit in the constant run mode. In
this mode, the compressor runs continuously, loading
and unloading in response to air demand. It will contin-
ue to run until stopped, either manually or by a protec-
tive shutdown. The LED is illuminated at all times while
running in this mode.
“AUTO LEAD” Button With LED – This button is used
to operate the unit in “Auto–Start–Timed–Stop” mode,
either by itself, or as the lead compressor in a Lead/Lag
arrangement. Loading and unloading occurs as in the
“CONSTANT RUN” mode, however, if the compressor
runs unloaded for a period of 10 minutes, the unit is
stopped. At this point, the compressor remains in the
“AUTO LEAD” mode and will restart when the system
pressure reaches the ’load’ setpoint programmed into
the controller. The LED will remain illuminated through-
out the cycle.
Automatic restarting or electrical
shock can cause injury or death.
Open, tag and lockout main discon-
nect and any other circuits before
servicing the unit.
“AUTO LAG” Button With LED – This button is used
to select the ’lag’ unit in a lead–lag arrangement. Op-
eration is identical to “AUTO LEAD” except that the
start–load and unload setpoints are automatically 5 PSI
lower than programmed.
Any mode may be selected at any time
without stopping the compressor.
“HIGH AIR TEMPERATURE” LED – This LED is used
to indicate an over temperature condition at either the
compressor or oil separator discharge. At the time of a
high temperature shutdown, the LED is illuminated and
the temperature digital readout is locked on to the of-
fending temperature. Illumination of the decimal point
in the lower right hand corner of the digital readout indi-
cates that the temperature displayed is at the oil sepa-
rator. A non–illuminated decimal point indicates com-
pressor discharge. Pressing “STOP/RESET” will
extinguish the LED (if the temperature has lowered be-
low 225
_
F) and revert the digital readout to displaying
actual discharge temperature.
“MOTOR OVERLOAD” LED – This LED indicates that
one of the motor overload relays has tripped. The over-
load relay itself must be reset before pressing “STOP/
RESET” will extinguish the LED.
“CHANGE SEPARATOR” LED – This LED flashes
when the differential pressure across the oil separator
reaches approximately 8 PSI. At this point, schedule
the separator element for service at the earliest oppor-
tunity. (See Section 5, pages 27 and 28, for separator
maintenance.)
Should the condition be ignored and allowed to further
deteriorate, the compressor will be shutdown and the
LED illuminated steadily when the differential pressure
reaches 15 PSI.
Machine damage will occur if com-
pressor is repeatedly restarted after
any one of the shutdown modes
stops operation of the unit. Find and
correct the malfunction before re-
suming operation.
“CHANGE AIR FILTER” LED – This LED is used to
signal when the air filter requires servicing or changing.
It is a reminder only and will not stop or impede the op-
eration of the unit. Operating the compressor with the
LED illuminated risks collapse of the filter and ingestion
into the compressor.
Содержание EBB BB-7.5 HP
Страница 12: ...13 8 612 Page 2 FIGURE 1 2 PACKAGE COMPRESSOR MOTOR SIDE FIGURE 1 3 PACKAGE BELT GUARD SIDE...
Страница 13: ...13 8 612 Page 3 FIGURE 1 4 PACKAGE CONTROLLER END...
Страница 16: ...13 8 612 Page 6 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Страница 17: ...13 8 612 Page 7 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Страница 32: ...13 8 612 Page 22 FIGURE 4 7 AUTO SENTRY S SOLID STATE CONTROL TOUCH PAD...
Страница 33: ...13 8 612 Page 23 200EBB546 Ref Drawing FIGURE 4 8 WIRING DIAGRAM...
Страница 53: ...13 8 612 Page 43 PIPING AND MOUNTING GROUP 213EBB810 B Ref Drawing...
Страница 61: ...13 8 612 Page 51 ELECTRICAL GROUP 205EBB810 A Ref Drawing For Parts List Refer to Pages 52 thru 54...
Страница 72: ...13 8 612 Page 62 FIGURE 11 4 REFRIGERATED DRYER FIGURE 11 5 SUCTION PRESSURE GAUGE DRYER INLET AND OUTLET...
Страница 73: ...13 8 612 Page 63 FIGURE 11 6 CONDENSER HEAT EXCHANGER HOT GAS BYPASS FIGURE 11 7 COMPRESSOR REFRIGERATED DRYER...
Страница 77: ...13 8 612 Page 67 INTEGRATED DRYER ASSEMBLY AND PIPING 301EBB810 A Ref Drawing...
Страница 82: ...13 8 612 Page 72 300EBB541 B Ref Drawing...
Страница 84: ......