13-10-615 Page 69
SYMPTOM
POSSIBLE
CAUSE
REMEDY
Oil carryover
1.
Overfilling the reservoir.
1.
Drain excess oil from
system.
2.
Clogged, broken or loose
oil return lines.
2.
Tighten or replace faulty
lines.
3. Ruptured
oil
separator
element.
3. Replace
element.
4.
Loose assembly.
4.
Tighten all fittings and
gaskets.
5.
Foam caused by use of
incorrect oil.
5. Use
Gardner
Denver
AEON 2000, 4000 or
9000SP lubricating
coolant.
6. Inoperative
minimum
pressure valve.
6.
Clean out or replace
valve.
7.
Operation at elevated
discharge temperatures.
7.
Reduce temperature. See
“High Discharge Air
Temperature”, this
section.
8.
Scavenge line check valve
failure.
8.
Replace check valve.
9.
Water condensate in oil
9.
Check oil reservoir
temperature, and if low,
change thermal mixing
valve element to higher
temperature.
NOTICE
Gardner Denver factory remanufactured replacement compressor airend units
are available from your authorized distributor, on an exchange basis, for all
rotary screw compressor units.
Содержание AUTO SENTRY EAU99P
Страница 13: ...13 10 615 Page 12 Figure 1 6 PACKAGE AIR OIL FLOW DIAGRAM 202EDM797 Ref Drawing ...
Страница 35: ...13 10 615 Page 34 Figure 4 7 CONTROL SCHEMATIC COMPRESSOR AT FULL LOAD 206EAU797 B Ref Drawing ...
Страница 38: ...13 10 615 Page 37 Figure 4 10 WIRING DIAGRAM WYE DELTA ES CONTROLLER AIR COOLED 202EAU546 D Ref Drawing ...
Страница 40: ...13 10 615 Page 39 205EAU546 D Ref Drawing Page 2 of 2 ...
Страница 44: ...13 10 615 Page 43 Figure 5 3 FLOW DIAGRAM 210EAU797 B Ref Drawing ...