thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAfEty

1.1.    

ElECtRiCAl SAfEty

 

‰

  

wARninG!

 It is the user’s responsibility to check the following:

 

Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and    

 

all electrical connections for wear and damage. Sealey recommend that an RCd (Residual Current device) is used with all electrical  

 

products. You may obtain an RCd by contacting your local Sealey dealer. 

 

If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable  

 

 

Appliance Test) tested.

 

Electrical safety information, it is important that the following information is read and understood.

1.1.1.   

ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. 

1.1.2.   

Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

1.1.3. 

  

important

: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the    

 

correct fuse - see fuse rating in these instructions.

 

8

   DO  nOt

 pull or carry the appliance by the power cable.

 

8

  

DO nOt

 pull the plug from the socket by the cable. 

 

8

   DO  nOt

 use worn or damaged cables, plugs or connectors. ensure that any faulty item is repaired or is 

  replaced immediately by a qualified electrician.

1.1.4. 

  

This product is fitted with a BS1363/A 13 Amp 3 pin plug. 

        

 If the cable or plug is damaged during use, switch the electricity supply and remove from use. 

        

 Ensure that repairs are carried out by a qualified electrician.

        

 Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.

 

 a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

 b) Connect the BROWN live wire to the live terminal ‘L’.

 

 c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

       

 ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

        

 Sealey recommend that repairs are carried out by a qualified electrician. 

1.2.    GEnERAl SAfEty 

 

9

   Familiarise yourself with the application and limitations of the compressor.

 

9

   Ensure the compressor is in good order and condition before use. If in any doubt do not use the unit and contact an electrician/service  

 agent.

 

‰

   wARninG! Compressor must only be serviced by an authorised agent. DO nOt tamper with, or attempt to adjust, pressure  

  switch or safety valve.

 

9

   Before moving, or maintaining the compressor ensure it is unplugged from the mains supply and that the air tank pressure has been  

 vented.

 

9

   Maintain the compressor in good condition and replace any damaged or worn parts. Use genuine parts only. 

Unauthorised parts may be  

  dangerous and will invalidate your warranty.

 

9

   Read the instructions relating to any accessory to be used with this compressor. ensure the safe working pressure of any air appliance  

 used 

exceeds compressors output pressure. If using a spray a gun, check that the area selected for spraying is provided with an air    

  change/ventilation system.

 

9

   ensure the air supply valve is turned off before disconnecting the air supply hose.

 

9

   To move the compressor use the handle only. Maintain unit’s centre of gravity when lifting. 

DO nOt

 attempt to lift or move the  

 

  compressor by any other means. 

 

9

   Use the compressor in a well ventilated area and ensure it is placed on a firm surface.

 

9

   Keep tools and other items away from the compressor when it is in use, and keep area clean and clear of unnecessary items.

 

9

   ensure the air hose is not tangled, twisted or pinched.

 

9

   Keep children and unauthorised persons away from the working area.

 

8

  

DO nOt

 dis-assemble compressor for any reason. The unit must be checked by qualified personnel only.

 

8

  

DO nOt

 use the compressor outdoors, or in damp, or wet, locations.

 

8

  

DO nOt

 operate within the vicinity of flammable liquids, gases or solids.

 

8

  

DO nOt

 touch compressor cylinder, cylinder head or pipe from head to tank as these may be hot.

 

8

  

DO nOt

 use this product to perform a task for which it has not been designed.

 

8

  

DO nOt

 deface the certification plate attached to the compressor tank.

Recommended fuse rating

13 Amp

S

AC5030VE.V3 Issue 1 24/01/19

Original Language Version

© Jack Sealey limited

Refer to 

instructions

Wear eye 

protection

Wear ear 

protection

ensure oil level 

is correct before 

first use

WARNING:

High Voltage

WARNING:

Hot surface

WARNING:

Automatic 

start up

Indoor use only

DO nOt

 open 

the air cock 

before an air 

hose is attached

Содержание SAC5030VE.V3

Страница 1: ...utral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 2 GENERAL SAFETY 9 9 Familiarise yourself with the application and limitations of the compressor 9 9 Ensure the compressor is in good order and condition before use If in any doubt do not use the unit and c...

Страница 2: ...s supplied 4 5 Attach handle with screw provided 4 6 The compressor should be operated on a flat surface or one that does not exceed 10 either transversely or longitudinally fig 1 and should be in a position that allows good air circulation around the unit 4 7 Remove the plastic transit plug from the oil filler hole 4 8 Before using the compressor check the oil level by referring to the oil sight ...

Страница 3: ...pressor disconnect from electricity supply and release all air from the tank In order to keep the compressor in good working condition periodical maintenance is essential 6 1 After the first 50 working hours replace the lubricating oil see Item 6 3 6 2 Operations to be carried out daily 6 2 1 Drain condensation place a container under the valve and open the valve by turning anti clockwise fig 5 Re...

Страница 4: ...l for 30 minutes then press reset button 2 Reset fuse and restart unit If repeated tripping occurs replace the check valve or contact Authorised Service Agent Compressor stops and will not restart Motor failure Contact Authorised Service Agent Compressor does not stop at maximum pressure 1 Pressure switch fault 2 Filter clogged 3 Head gasket or valve fault 1 Contact Authorised Service Agent 2 Repl...

Отзывы: