background image

InstructIons for:

COMPRESSOR 24LTR diRECT dRivE 2HP

110v

model no:

  

SAC2420E110v.v2

thank you for purchasing a sealey product. manufactured to a high standard this product will, if used according to these instructions and properly 

maintained, give you years of trouble free performance.

1.  SAFETY iNSTRUCTiONS

IMPORTANT:

 

PLEASE REAd THESE iNSTRUCTiONS CAREFULLY. NOTE THE SAFE OPERATiONAL REQUiREMENTS, WARNiNGS & CAUTiONS. 

USE THE PROdUCT CORRECTLY ANd WiTH CARE FOR THE PURPOSE FOR WHiCH iT iS iNTENdEd. FAiLURE TO dO SO MAY CAUSE dAMAGE 

OR PERSONAL iNJURY ANd WiLL iNvALidATE THE WARRANTY. PLEASE KEEP iNSTRUCTiONS SAFE FOR FUTURE USE.

 

    

iMPORTANT!

 the use of extension leads to connect this 

 

   

compressor to the mains is not recommended as the resulting   

   

voltage drop reduces motor, and therefore pump performance.

1.2.   GENERAL SAFETY 

3   

familiarise yourself with the application and limitations of the    

   

compressor.   

 

3   

ensure the compressor is in good order and condition before    

   

use. If in any doubt do not use the unit and contact an  

 

   

electrician/service agent.

   

WARNiNG! 

Compressor must only be serviced by an  

 

   

authorised agent. DO NOT tamper with, or attempt to  

 

   

adjust, pressure switch or safety valve.

3   

Before moving, or maintaining the compressor ensure it is  

 

   

unplugged from the mains supply and that the air tank  

 

   

pressure has been vented. 

3   

maintain the compressor in good condition and replace any    

   

damaged or worn parts. use genuine parts only. 

Unauthorised  

   

parts may be dangerous and will invalidate your warranty.

3   

read the instructions relating to any accessory to be used  

 

   

with this compressor. ensure the safe working pressure of any  

   

air appliance used exceeds compressors output pressure. If    

   

using a spray gun, check that the area selected for spraying is   

   

provided with an air change/ventilation system.

3   

ensure the air supply valve is turned off before disconnecting    

   

the air supply hose.

3   

to move the compressor, use the handle only. maintain unit’s    

   

centre of gravity when lifting. 

dO NOT

 attempt to lift or move    

   

the compressor by any other means. 

3   

use the compressor in a well ventilated area and ensure it is    

   

placed on a firm surface.

3   

Keep tools and other items away from the compressor when    

   

it is in use, and keep area clean and clear of unnecessary  

 

   items.

3   

ensure the air hose is not tangled, twisted or pinched.

3   

Keep children and unauthorised persons away from the  

 

   

working area.

© Jack sealey limited

1.1.  ELECTRiCAL SAFETY

  

WARNiNG!

 It is the responsibility of the owner and the operator 

to read, understand and comply with the following: You must check 

all electrical products before use to ensure that they are safe. You 

must inspect power cables, plugs, sockets and any other connectors 

for wear or damage. You must ensure that the risk of electric shock 

is minimised by the installation of appropriate safety devices. A 

residual current circuit Breaker (rccB) should be incorporated in 

the main distribution board. We also recommend that a residual 

current device (rcd) is used. It is particularly important to use an 

rcd with portable products that are plugged into a supply which is 

not protected by an rccB. If in any doubt consult a qualified 

electrician. You may obtain a residual current device by contacting 

your sealey dealer. You must also read and understand the 

following instructions concerning electrical safety:

1.1.1. the 

Electricity at Work Act 1989

 requires that all portable  

    electrical appliances, if used on business premises, are  

    tested by a qualified electrician, using a Portable Appliance  

    tester (PAt), at least once a year.

1.1.2. the 

Health & Safety at Work Act 1974

 makes owners of  

    electrical appliances responsible for the safe condition of  

    those appliances and the safety of the appliance operators. 

  

if in any doubt about electrical safety, contact a qualified  

  electrician.

1.1.3. ensure that the insulation on all cables and on the appliance  

    is safe before connecting it to the power supply. see 1.1.1.  

    and 1.1.2. and use a Portable Appliance tester.

1.1.4. ensure that cables are always protected against short circuit  

  and 

overload.

1.1.5. regularly inspect power supply cables and plugs for wear or  

  damage and check all connections to ensure that none are  

  loose.

1.1.6. 

important:

 ensure that the voltage marked on the appliance  

    matches the power supply to be used and that the plug is  

    fitted with the correct fuse.

1.1.7. 

dO NOT

 pull or carry the appliance by the power cable.

1.1.8. 

dO NOT

 pull the plug from the socket by the cable.

1.1.9. 

dO NOT

 use worn or damaged cables, plugs or connectors.  

    Immediately have any faulty item repaired or replaced by a  

    qualified electrician. When a Bs en 60309 plug is damaged,  

    cut the cable just above the plug and dispose of the plug  

  safely. 

 

 fit a new plug according to the following instructions:

 

 a) Connect the GREEN/YELLOW earth wire to the   

 

    earth terminal. 

 

 

 

 

 

 b) Connect the BROWN live wire to the live terminal ‘L’.

  

c) Connect the BLUE      

 

     neutral wire to the    

 

    neutral terminal ‘N’.

 

 d) After wiring, check   

 

that there are no bare   

 

wires, that all wires    

 

have been connected   

 

correctly, that the cable  

 

outer insulation extends  

 

 beyond the cable

 

restraint and that the   

 

restraint is tight. 

NOTE: if using a transformer  

 

to supply the  

 

 

compressor, it must be  

 

rated at a minimum of  

 

2kvA to allow the  

 

 

compressor to run    

 efficiently.

Original Language Version

 sAc2420e110V.V2  Issue no:1 - 17/03/14

 FiG.1

Содержание SAC2420E110V.V2

Страница 1: ...ctrical products before use to ensure that they are safe You must inspect power cables plugs sockets and any other connectors for wear or damage You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices A Residual Current Circuit Breaker RCCB should be incorporated in the main distribution board We also recommend that a Residual Current Device R...

Страница 2: ...tly coupled to a heavy duty induction motor for reliable operation Welded tank complies with latest European standards Fitted with fully automatic pressure cut out switch with twin gauges displaying tank and working pressures Fitted with BS EN 60309 approved 16A 110V plug 3 PREPARATION assembly 3 1 Remove the compressor from its packaging and inspect for any shortages or damage If anything is foun...

Страница 3: ...rs replace the lubricating oil see para 6 4 6 2 Operations to be carried out daily a Drain condensation place a container under the valve and open the valve by turning anti clockwise fig 1 Retighten the valve b Check that all nuts and bolts are tight particularly those retaining the crankcase and cylinder head fig 5 When the compressor is not being used set the regulated pressure to zero so as to ...

Страница 4: ...ressor does not stop at max pressure Filter clogged Head gasket or valve fault Replace filter element Contact Authorised Service Agent 7 Compressor noisy with metallic knock Bearing or piston damage Contact Authorised Service Agent 8 Excessive moisture in discharged air High humidity environment Drain tank after each use NOTE It is our policy to continually improve products and as such we reserve ...

Отзывы: