background image

Description

Air compressor units are intended 
to provide compressed air to power 
pneumatic tools, operate spray guns 
and supply air for pneumatic valves and 
actuators. The pumps supplied with 
these units have oil lubricated bearings. 
A small amount of oil carryover is 
present in the compressed air stream. 
Applications requiring air free of oil 
vapor should have the appropriate 
filter installed. The air compressor units 
are to be mounted per the instructions 
provided on a solid floor. Any other use 
of these units will void the warranty 
and the manufacturer will not be 
responsible for problems or damages 
resulting from such misuse. Refer to the 
enclosed Replacement Parts Manual to 
identify compressor as single stage or 
two-stage.

Safety Guidelines

This manual contains information 
that is very important to know 
and understand. This information 
is provided for SAFETY and to 
PREVENT EQUIPMENT PROBLEMS. 
To help recognize this information, 
observe the following symbols. 

 

Danger indicates 

  an imminently 

hazardous situation which, if not 
avoided, WILL result in death or 
serious injury.
 

Warning indicates 

  a potentially 

hazardous situation which, if not 
avoided, COULD result in death or 
serious injury.
 

Caution indicates 

  a potentially 

hazardous situation which, if not 
avoided, MAY result in minor or 
moderate injury.
 

Notice indicates 

  important 

information, that if not followed, 
may cause damage to equipment.

Air Compressors

Record the Model No., Serial No. and 
date of purchase in the space below.

Model No.  ______________________

Serial No. 

______________________

Date of purchase  _________________

Retain these numbers for  

future reference.

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the 
product described. Protect yourself and others by observing all safety information. Failure to comply with instructions 
could result in personal injury and/or property damage! Retain instructions for future reference.

See Warranty on page 10 for important information about commercial use of this product.

Operating Instructions 

TF2101, TF2111, TQ3010, TQ3011, TX2101, TX2118

REMINDER: Keep your dated proof of purchase for warranty purposes! 

Attach it to this manual or file it for safekeeping.

Unpacking

When unpacking unit, inspect carefully 
for any damage that may have occurred 
during transit. Make sure any loose 
fittings, bolts, etc., are tightened before 
putting unit into service. In case of 
questions, damaged or missing parts, 
please call 1-800-543-6400 for customer 
assistance. Have the serial number, 
model number, and parts list (with 
missing parts circled) before calling.

DO NOT RETURN  
THE PRODUCT TO  
THE RETAILER!

 

Do not operate  

  unit if damaged 

during shipping, handling or use. 
Damage may result in bursting and 
cause injury or property damage.

READ & FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

DO NOT DISCARD

General Safety

CALIFORNIA PROPOSITION 65

 

This product or its  

  power cord may 

contain chemicals, including lead, 
known to the State of California 
to cause cancer and birth defects 
or other reproductive harm. Wash 
hands after handling.
 

You can 

  create 

dust when you cut, sand, 
drill or grind materials 
such as wood, paint, 
metal, concrete, cement, or other 
masonry. This dust often contains 
chemicals known to cause cancer, 
birth defects, or other reproductive 
harm. Wear protective gear.

STOP�

IN255005AV 2/12

© 2012

REGISTER YOUR PRODUCT ONLINE NOW!     http://www.chpower.net/reg

Breathable Air Warning

This compressor/pump is NOT 
equipped and should NOT be 
used “as is” to supply breathing 
quality air. For any application of 
air for human consumption, you 
must fit the air compressor/pump 
with suitable in-line safety and 
alarm equipment. This additional 
equipment is necessary to 
properly filter and purify the air 
to meet minimal specifications 
for Grade D breathing as 
described in Compressed 
Gas Association Commodity 
Specification G 7.1, OSHA 29 
CFR 1910. 134, and/or Canadian 
Standards Associations (CSA).

DISCLAIMER OF WARRANTIES
In the event the compressor is 
used for the purpose of breathing 
air application and proper in-line 
safety and alarm equipment 
is not simultaneously used, 
existing warranties are void, and 
the manufacturer disclaims any 
liability whatsoever for any loss, 
personal injury or damage.

All manuals and user guides at all-guides.com

Содержание TF2101

Страница 1: ... product Operating Instructions TF2101 TF2111 TQ3010 TQ3011 TX2101 TX2118 REMINDER Keep your dated proof of purchase for warranty purposes Attach it to this manual or file it for safekeeping Unpacking When unpacking unit inspect carefully for any damage that may have occurred during transit Make sure any loose fittings bolts etc are tightened before putting unit into service In case of questions d...

Страница 2: ...nts from bursting The flow rating can be found in the parts manual The maximum safe pressure rating for the pump is 200 psi two stage or 150 psi single stage The safety valve in the intercooler does not provide system protection Maximum operating pressure is 175 psi for two stage compressors and 135 psi for single stage compressors Do not operate with pressure switch or pilot valves set higher tha...

Страница 3: ...ty valve setting Incorrect selection and installation of any tube pipe or hose could result in bursting and injury Connect piping system to tank using the same size fitting as the discharge port INSTALLING A SHUT OFF VALVE A shut off valve should be installed on the discharge port of the tank to control the air flow out of the tank The valve should be located between the tank and the piping system...

Страница 4: ... the applicable article For Motors and Motor Controllers Article 430 Table 430 1 52 IMPORTANT Overload protection is required for all motors Certain motors have this protection built in To determine if a motor has built in overload protection refer to the frame size on the motor nameplate Motors with frame size R56HZ Y56Y or L143T include built in overload protection No additional protection is re...

Страница 5: ... Mobil 1 5W30 or 10W30 synthetic oil may also be used Add oil only through the oil fill plug Pouring oil into any other orifice will cause oil to leak and spray out during operation TF2101 TF2111 TQ3010 TQ3011 TX2101 TX2118 5 L1 L2 T2 T1 X2 T2 X2 L1 L2 L3 T3 T1 Fill to the center of the sight gauge or maximum mark on dipstick see Figure 5 Using any other type of oil may shorten pump life and damag...

Страница 6: ...e Disconnect tag and lock out power source then release all pressure from the system before attempting to install service relocate or perform any maintenance In order to maintain efficient operation of the compressor system check the air filter and oil level before each use The ASME safety valve should also be checked daily See Figure 8 Pull ring on safety valve and allow the ring to snap back to ...

Страница 7: ...elts Slots in the bed plate allow for sliding the motor back and forth to adjust belt tension STORAGE If compressor is to be stored for a short period of time make sure that it is stored in a normal position and in a cool protected area B C Air Compressor Motor Flywheel Straight Edge Setscrew Motor Drive Pulley Figure 9 Top View Troubleshooting Chart Symptom Possible Cause s Corrective Action Moto...

Страница 8: ...n 3 Check tank for cracks or pin holes 3 Replace tank Never repair a damaged tank Excessive belt wear Light dust from start is normal Worn belts separate at layers 1 Pulley out of alignment 1 Realign motor pulley 2 Belts too tight or too loose 2 Adjust tension Tank pressure builds slowly 1 Dirty air filter 1 Clean or replace filter element 2 Blown cylinder head gasket 2 Install new gasket 3 Worn b...

Страница 9: ...TF2101 TF2111 TQ3010 TQ3011 TX2101 TX2118 9 Service Record Date Maintenance Performed Replacement Components Required All manuals and user guides at all guides com ...

Страница 10: ...ontact with tools or surroundings b Pump or valve failure caused by rain excessive humidity corrosive environments or other contaminants c Cosmetic defects that do not interfere with compressor functionality d The following components are considered normal wear items and are not covered after the first year of ownership Electric motor check valve pressure switch regulator pressure gauges hose tubi...