background image

270L BELT DRIVE AIR COMPRESSOR 7.5HP 
3PH

MODEL NO: 

SAC32775B

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 
instructions, and properly maintained, give you years of trouble free performance.

I

MP

PO

R

RTA

TANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

TH

HE

P

PR

O

ODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR

PE

ER

S

SON

NAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1. SAFETY

1.1. 

ELECTRICAL SAFETY

WARNING!

Electrical installation of compressor to a 3-phase 415volt supply must only be carried out by a qualified electrician.

 

  Make sure the power supply cable is correctly connected to the earth. It is the user’s responsibility to read, understand and comply  

 

  with the following:

 

  You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads,  

 

  plugs and all electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation  

 

  of appropriate safety devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board.

 

  You must also read and understand the following instructions concerning electrical safety.

   The Electricity At Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a  

 

 quali

fi

 ed electrician, using a Portable Appliance Tester (PAT), at least once a year.

   The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of the appliance and   
  the safety of the appliance operator. If in any doubt about electrical safety, contact a qualified electrician.

   Ensure insulation on all cables and the product itself is safe before connecting to mains power supply. 

   Ensure that cables are always protected against short circuit and overload.

   Regularly inspect power supply, leads, plugs and all electrical connections for wear and damage, especially power connections, to    
  ensure that none are loose.

WARNING! IMPORTANT: 

Ensure the voltage marked on the product is the same as the electrical power supply to be used, and  

 

check that plugs are fitted with correct capacity fuse.

DO NOT

 pull or carry the powered appliance by its power supply lead or output cables.

DO NOT

 pull power plugs from sockets by the power cable.

DO NOT

 use worn or damaged leads, plugs or connections. Immediately replace or have repaired by a qualified electrician.  

 

  These particular compressors are supplied without a mains plug. Follow the instructions below regarding the fitting of an appropriate  
 plug.

1.2. 

  

Model SAC32775B requires a 415v 3 phase supply and must have an appropriate plug added.

WARNING!

 Electrical installation of the compressor to a 3 phase 415 volt supply must only be carried out by a qualified electrician.    

Ensure the power supply cable is connected to the Earth.

1.2.1. 

  

This product must be fitted with a 3 phase plug wired as illustration in (fig.1), wired to an appropriately  

 

 

 

 fused 

supply.

 

  Connect GREEN/YELLOW wire to Earth ‘E’

 

  Connect BROWN wire to L1 Terminal.

 

  Connect  BLACK wire to L2 Terminal.

 

  Connect the GREY wire to L3 Terminal.

WARNING!

 It is essential to observe acw (fig 1) Pulley direction on initial start up. If cw  

 

 

 

 

 

  observed, stop immediately and consult a qualified electrician to invert 2 phases.

  

NOTE:

 The cable core colours found in the mains cable on this compressor are consistent  

 

 

 

 

 

  with Amendment 2 to 7671:2001. When completed, check there are no bare wires, that all   

 

 

 

 

 

  wires have been connected correctly and the cable restraint is tight.

DO NOT

 use this product with a standard extension cable. Only use ARMOURED extension cable.

 

  IMPORTANT USER INFORMATION!

 Over-current protection of the power circuit is required in                                           

 

 

  accordance with 7.2 of EN 60204-1:2006. The supply disconnecting device to be in accordance with 5.3 of EN 60204-1:2006.  

 

 

  Ask a qualified electrician about compliance. The use of extension leads to connect these compressors to the mains is not  

 

  

recommended.

SAC32775B  Issue 1 31/03/22

Original Language Version

© Jack Sealey Limited

Refer to 

instructions

Electrical shock 

hazard

Warning: 

hot surfaces

Wear eye 

protection

Wear ear 

protection

Wear protective 

clothing

Warning

 

 

 

 

 

 

 

   

fi

 g.1

Warning

automatic

start up

Warning:

Under pressure

Switch o

 

before servicing 

or maintenance

Belt guard

must be in

place

DO NOT

Connect face 
mask directly

to compressor 

DO NOT

open the air

cock before

an air hose is

attached

Содержание SAC32775B

Страница 1: ... Ensure the voltage marked on the product is the same as the electrical power supply to be used and check that plugs are fitted with correct capacity fuse DO NOT pull or carry the powered appliance by its power supply lead or output cables DO NOT pull power plugs from sockets by the power cable DO NOT use worn or damaged leads plugs or connections Immediately replace or have repaired by a qualifie...

Страница 2: ... to the compressor tank DO NOT cover the compressor or restrict air flow around the unit whilst operating DANGER DO NOT direct the output jet of air towards people or animals DO NOT operate the compressor without an air filter DO NOT allow anyone to operate the compressor unless they have received full instructions WARNING The air tank is a pressure vessel and the following safety measures apply D...

Страница 3: ... compressor running with no air line or tools connected Make sure that the pressure in the tank rises and that the compressor stops automatically when the maximum pressure is reached This value is written on the specification plate and may take in excess of 5 minutes The compressor will now operate automatically The pressure switch fig 6 stops the motor when the maximum tank pressure is reached an...

Страница 4: ...SURE SYSTEMS SAFETY REGULATIONS 2000 it is the responsibility of the owner of the compressor to initiate a system of inspection that both defines the frequency of the inspection and appoints a person who has specific responsibility for carrying out the inspection 7 TROUBLESHOOTING FAULT POSSIBLE CAUSE REMEDY 1A Pressure drop in the tank Air leaks at connections Run compressor to maximum pressure s...

Страница 5: ...applicable into approved containers and dispose of the product and fluids according to local regulations WEEE REGULATIONS Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authori...

Отзывы: