13-10-615 Page 20
BLOWDOWN VALVE PIPING
- The blowdown valve is piped back into the airend between the inlet valve
and air filter.
WATER PIPING (Water-Cooled Heat Exchanger Models Only)
- On machines equipped with water-
cooled heat exchangers, the water inlet and outlet connections are located in the unit base flange.
It is mandatory that any water cooled unit be installed in a shelter heated to
temperatures above freezing (32
°
F., 0
°
C).
The water source should be capable of supplying up to the maximum flow shown in Figure 2-5, page 19,
and Figure 2-6, page 19, at a minimum pressure of 40 psig (2.8 bar); maximum allowable water pressure
is 150 psig (10.3 bar). The water flow rates shown are approximate and a guide to sizing piping, cooling
tower and other water system equipment.
The heat exchanger system is designed to operate with water inlet temperatures from 60
°
F to 90
°
F
(16
°
C to 32
°
C) and a water outlet temperature not to exceed 110
°
F (43
°
C). If water cooler than 60
°
F
is used, high water outlet temperatures (over 110
°
F, 43
°
C) will be experienced along with shortened
heat exchanger life caused by tube fouling and corrosion. If water warmer than 90
°
F (32
°
C) is used,
higher compressor oil inlet temperatures and high water usage will result.
Most water systems will require control of impurities: filtration, softening or other treatment. See
“Compressor Oil Cooler - Water-Cooled Heat Exchanger”, page 54 for more information on the water
system.
Figure 2-7 – SERIES PIPING
SERIES PIPING
(Figure 2-7, page 20) - Water flow must be through aftercooler first for effective cooling
of discharge air and is so piped on the standard water-cooled unit.
305EAQ797-A
(Ref. Drawing)
C
C
C
A
A
A
U
U
U
T
T
T
I
I
I
O
O
O
N
N
N
Содержание AUTO SENTRY EAU99P
Страница 13: ...13 10 615 Page 12 Figure 1 6 PACKAGE AIR OIL FLOW DIAGRAM 202EDM797 Ref Drawing ...
Страница 35: ...13 10 615 Page 34 Figure 4 7 CONTROL SCHEMATIC COMPRESSOR AT FULL LOAD 206EAU797 B Ref Drawing ...
Страница 38: ...13 10 615 Page 37 Figure 4 10 WIRING DIAGRAM WYE DELTA ES CONTROLLER AIR COOLED 202EAU546 D Ref Drawing ...
Страница 40: ...13 10 615 Page 39 205EAU546 D Ref Drawing Page 2 of 2 ...
Страница 44: ...13 10 615 Page 43 Figure 5 3 FLOW DIAGRAM 210EAU797 B Ref Drawing ...