InstructIons for:
COMPRESSORS 200 / 270 / 270ltr bElt dRivE 5.5 /
7.5 / 10hp, 3Ph 2-StagE
moDEL no's:
SaC42055b, SaC52775b, SaC62710b
thank you for purchasing a sealey product. manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT:
PlEaSE REad thESE iNStRUCtiONS CaREFUllY. NOtE thE SaFE OPERatiONal REQUiREMENtS, WaRNiNgS aNd
CaUtiONS. USE thE PROdUCt CORRECtlY aNd With CaRE FOR thE PURPOSE FOR WhiCh it iS iNtENdEd. FailURE tO dO SO MaY
CaUSE daMagE aNd/OR PERSONal iNJURY aNd Will iNvalidatE thE WaRRaNtY. PlEaSE KEEP iNStRUCtiONS SaFE FOR FUtURE USE.
1. SaFEtY iNStRUCtiONS
1.1. ElECtRiCal SaFEtY
WaRNiNg! ElEcTRIcAl INsTAllATION Of cOMPREssOR TO A 3-PhAsE 415 VOlT suPPly MusT ONly bE
cARRIEd OuT by A quAlIfIEd ElEcTRIcIAN.
Make sure the power supply cable is correctly connected to the earth. It is the user’s responsibility to read, understand and comply
with the following:
You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads,
plugs and all electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of
appropriate safety devices. An rccB (residual current circuit Breaker) should be incorporated in the main distribution board.
you must
also read and understand the following instructions concerning electrical safety.
1.1.1. the
Electricity At Work Act 1989
requires all portable electrical appliances, if used on
business premises, to be tested by a qualified electrician, using a Portable Appliance
tester (PAt), at least once a year.
1.1.2. the
health & safety at Work Act 1974
makes owners of electrical appliances responsible for
the safe condition of the appliance and the safety of the appliance operator.
If in any doubt
about electrical safety, contact a qualified electrician.
1.1.3. Ensure insulation on all cables and the product itself is safe before connecting to mains power
supply.
1.1.4. Ensure that cables are always protected against short circuit and overload.
1.1.5. regularly inspect power supply, leads, plugs and all electrical connections for wear and damage,
especially power connections, to ensure that none is loose.
1.1.6.
Important:
Ensure the voltage marked on the product is the same as the electrical power supply
to be used. A three phase plug must be fitted to this machine.
1.1.7. Do not pull the powered appliance by the power cable.
1.1.8. Do not pull power plugs from sockets by the power cable.
1.1.9. Do not use worn or damage leads, plugs or connections. Immediately replace or have repaired by a qualified electrician.
1.1.10.
This product must be fitted with a 3-phase plug according to the diagram, and will require a minimum of 16 amps per phase,
(preferably 32 amp) electrical supply. you must contact a qualified electrician to ensure an appropriately fused supply is
available.
Connect gREEN/YEllOW wire to earth (E) terminal.
Connect the live wires to live 1, 2 and 3. Check for the correct direction of rotation (see arrow on belt cage) to confirm
correct wiring of 3-phase plug when you first run the compressor.
When completed, check that there are no bare wires, that all wires have been connected correctly, that the cable
external insulation extends beyond the cable restraint and that the restraint is tight.
Original Language Version
sAc42055B, sAc52775B, sAc62710B Issue: 1 - 17/01/11