MG6000 Series Media Gateway User
’
s Manual
- 87 -
The config file name:sip6008etv385.img
5.1.14.6.2
Start to down load by HTTP
a). Configuration
IAD(8)#
set httpdownload-start
http content length is 2068532
2067168 bytes downloaded
Http Recv task over,length is 2068532 bytes
Flash writing... Wait a moment please!
erased 2816 kbytes ... 100% complete.
Save firmware to flash successfully!
Attention
:
a). First, make sure the HTTP server is enable.
b). Secondly, make sure the HTTP client and the HTTP server connect well, ping each other to check it.
c). Lastly
,
before input the command <set httpdownload-start>, user need to specify the address and the
port of HTTP server and the type of the file which can be application software, binary configuration file, text
configuration file, kernel file, DSP kernel file, and the update file name.
5.1.15
System clock
a). Configuration
IAD(8)#
set clock
->Please input year(2000-2099)[2008]:2008
->Please input month(1-12)[8]:8
->Please input date(1-31)[19]:19
->Please input clock(0-23) [12]:
->Please input minute(0-59) [0]:
->Please input second(0-59) [25]:
Succeed to Set Soft Time!
b). Display
IAD(8)#
show clock
2008-08-19 Tuesday 12:00:47
5.1.16
Display the history of command
Display the history of command that user input.
a). Disply
IAD(8)#
show history
set clock
show clock