Figure 6.1: Velocity Profiles of XYZ
Notes on Figure 6.1:
The X and Y axis have a ‘trapezoidal’ velocity profile, while the Z axis has a ‘triangular’
velocity profile. The X and Y axes accelerate to the specified speed, move at this constant speed, and then
decelerate such that the final position agrees with the command position, PR. The Z axis accelerates, but before the
specified speed is achieved, must begin deceleration such that the axis will stop at the commanded position. All 3
axes have the same acceleration and deceleration rate, hence, the slope of the rising and falling edges of all 3
velocity profiles are the same.
Independent Jogging
The jog mode of motion is very flexible because speed, direction and acceleration can be changed during motion.
The user specifies the jog speed (JG), acceleration (AC), and the deceleration (DC) rate for each axis. The direction
of motion is specified by the sign of the JG parameters. When the begin command is given (BG), the motor
accelerates up to speed and continues to jog at that speed until a new speed or stop (ST) command is issued. If the
jog speed is changed during motion, the controller will make a accelerated (or decelerated) change to the new speed.
An instant change to the motor position can be made with the use of the IP command. Upon receiving this
command, the controller commands the motor to a position which is equal to the specified increment plus the current
position. This command is useful when trying to synchronize the position of two motors while they are moving.
Note that the controller operates as a closed-loop position controller while in the jog mode. The DMC-40x0
converts the velocity profile into a position trajectory and a new position target is generated every sample period.
This method of control results in precise speed regulation with phase lock accuracy.
Command Summary - Jogging
COMMAND
DESCRIPTION
AC x,y,z,w
Specifies acceleration rate
BG XYZW
Begins motion
DC x,y,z,w
Specifies deceleration rate
IP x,y,z,w
Increments position instantly
IT x,y,z,w
Time constant for independent motion smoothing
JG +/-x,y,z,w
Specifies jog speed and direction
ST XYZW
Stops motion
Parameters can be set with individual axes specifiers such as JGY=2000 (set jog speed for Y axis to 2000).
DMC-40x0 User Manual
Chapter 6 Programming Motion
•
80
VELOCITY
(COUNTS/SEC)
20000
10000
5000
15000
20
40
60
80
TIME (ms)
100
X axis velocity profile
Y axis velocity profile
Z axis velocity profile
0
Содержание DMC-4040
Страница 17: ...DMC 4080 Layout Figure 2 2 Outline of the of the DMC 4080 DMC 40x0 User Manual Chapter 2 Getting Started 8...
Страница 19: ...DMC 4040 Dimensions Figure 2 5 Dimensions of DMC 4040 DMC 40x0 User Manual Chapter 2 Getting Started 10...
Страница 20: ...DMC 4080 Dimensions Figure 2 6 Dimensions of DMC 4080 Chapter 2 Getting Started 11 DMC 40x0 User Manual...
Страница 54: ...Chapter 3 Connecting Hardware 45 DMC 40x0 User Manual...
Страница 55: ...DMC 40x0 User Manual Chapter 3 Connecting Hardware 46...
Страница 56: ...Chapter 3 Connecting Hardware 47 DMC 40x0 User Manual...
Страница 73: ...Figure 4 1 GalilTools DMC 40x0 User Manual Chapter 4 Software Tools and Communication 64...
Страница 185: ...THIS PAGE LEFT BLANK INTENTIONALLY DMC 40x0 User Manual Chapter 7 Application Programming 176...
Страница 205: ...THIS PAGE LEFT BLANK INTENTIONALLY DMC 40x0 User Manual Chapter 10 Theory of Operation 196...
Страница 220: ...Step 2 Remove ICM For DMC 4040 Proceed to Step 3 Configure Circuit Appendices 211 DMC 40x0 User Manual...
Страница 222: ...Step 2 Remove ICM s Appendices 213 DMC 40x0 User Manual...
Страница 232: ...DMC 4080 Steps 4 and 5 Step 4 Replace ICM s Appendices 223 DMC 40x0 User Manual...