
- 13 -
2. Mixing using logic switches as ON/OFF switches is
forcibly switched to the condition single mode. Switching
to the condition group mode is impossible until the logic
switches are released.
PROGRAM MIXING [Model Menu]
Speed Mode
This function lets you set the operation switch at the program
mixing master side. The servo can be operated outside the set
curve by switch operation by using this function.
Setting method
1. Set program mixing to the curve mode. The ACT,
SWITCH, etc. setting screen shown above appears.
2. Use the cursor lever to move the cursor to speed mode
selection. Use the dial to select the master mode, and
push the DATA button.
3. Set the in speed and out speed.
4. Set the toggle switch to program mixing master.
5. When the switch set to master is operated, the master
position marker of the curve is shifted at the set servo
speed and the slave function operates along the curve
setting. In the below example, when SW-F is operated,
the slave auxiliary 1 function automatically operates
along the EXP1 curve.
MODEL TYPE [Linkage Menu]
The H-4X mode has been added to the swash types available.
The H-4X swash type is the same as the H-4 type, except the
control points are rotated 45 degrees.
MOTOR MIXING [Model Menu]
Motor mixing was added to airplane model. In addition, when
the power is turned on in the mixing on state, a warning
message is output.
SWASH RING [Model Menu]
This function limits the swash travel to within a fixed range to
prevent damaging of the swash ring by simultaneous operation
of the ailerons and elevators. It is effective in 3D aerobatics
which use a large travel.
Setting method
1. Open the swash ring setting screen by selecting
SWASH RING from the linkage menu.
2. The operating range display area mark shows the stick
position. The vertical direction shows the aileron travel.
When ACT is displayed by pushing the ACT/INH button,
the swash ring function is activated, and a circle is
displayed in the operating range display area. Stick
operation is limited to within the area of this circle.
3. Use the cursor lever to move the cursor to the rate
display. Use the dial to set the rate. The adjustment
range is 50~200%. Adjust the rate to maximum swash
tilt.
THROTTLE LIMITER [Model Menu]
This function sets the upper limit position of the throttle curve.
Limit position adjustment can be assigned to an arbitrary control.
Adjustment range upper and lower limits can be set.
Setting method
1. Open the throttle limiter setting screen by selecting THR
LIMITER from the Model Menu.
2. Use the cursor lever to move the cursor to the ACT/INH
display. Use the dial to select ACT, and push the DATA
button. ON or OFF is displayed.
3. Use the cursor lever to move the cursor to the SWITCH
display and push the DATA button. The switch selection
screen opens. Select the throttle limiter function ON/OFF
switch.
Switch
Combination logic
SW1
SW2
AND OR Ex-OR
off off off off off
off on off on on
on off off on on
on on on on off
Speed mode selection
Switched to condition single mode
Logic mode
Adjustment range gauge
Throttle curve
Limit control
Limit control position
Master: SW-F
Operating range
display area
ACT/INH
Rate
Содержание T12Z
Страница 16: ...16...