![Furuno FS-2575 Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/furuno/fs-2575/fs-2575_operators-manual_2349782054.webp)
5. ROUTINE MESSAGE CALLING, RECEVING
5-8
Sending message by NBDP terminal unit
The message “STATION ENTRY COMPLETED FROM DSC. Press any key to escape.”
appears on the screen of the NBDP terminal unit.
1. Press any key on the NBDP terminal unit to erase the message.
2. Press the function key
F3
on the keyboard of the NBDP terminal unit to open the
Operate menu.
3. Select Call Station and then press the
Enter
key.
4. DSC is selected; press the
Enter
key. Connect appears in reverse video.
5. Type and transmit your message.
6. When you finished sending your message, press the function key
F10
to disconnect the
line.
5.2.2
Receiving a group call
Group ID must be registered in order to receive a group call (see paragraph 6.15.3).
When a group call is received, the audio alarm sounds. The icon (
) on the tab area
flashes in black and white, and the pop-up message “GROUP MSG received! [CANCEL]:
Stop alarm” appears.
1. Press the
CANCEL
key to silence the audio alarm. The pop-up message disappears.
2. Press the
TAB
key to select the
icon.
3. Press the
ENTER
knob.
4. Rotate the
ENTER
knob to select ACTIVE and then press the
ENTER
knob.
5. Watch on the working frequency. Communicate by radiotelephone or NBDP (see
“Receiving message by NBDP terminal unit” on next page). If there is the difference
between the registered frequency and used frequency to receive, the pop-up message
appears. Select Agree for the voice communication, or Disagree when you do not
change the frequency.
6. After you finish communicating, rotate the
ENTER
knob to select QUIT and then press
the
ENTER
knob.
7. Rotate the
ENTER
knob to select CONTINUE and then press the
ENTER
knob to finish
communication.
Receiving message by NBDP terminal unit
After receiving a group call, confirm the following.
• The control unit’s screen shows “OCCUPIED” and the TX and RX frequencies.
• The message from the sending station appears on your NBDP terminal unit.
Содержание FS-2575
Страница 1: ...SSB RADIOTELEPHONE FS 2575 FS 5075 OPERATOR S MANUAL www furuno co jp MODEL...
Страница 14: ...SYSTEM CONFIGURATIONS xii This page is intentionally left blank...
Страница 28: ...2 SSB RADIOTELEPHONE 2 8 This page is intentionally left blank...
Страница 46: ...4 DISTRESS OPERATIONS 4 14 This page is intentionally left blank...
Страница 140: ...APPENDIX AP 4 Custom channels to be programmed by FURUNO dealers CH NO Ship Receive kHz Ship Transmit kHz Remarks...
Страница 162: ...APPENDIX AP 26 Control unit FS 2575C 05P0844 PANEL 05P0853 C IF 05P0852 C CPU Antenna Coupler AT 5075 05P0875 COUP...