Programming Guide
9-11
9.3. Back up battery
S153 Ver.2 has the backup battery other than the battery that operates the splicer. The backup
battery is for the calendar and the memory preservation. The backup battery is rechargeable.
When the S153 Ver.2 is turned on, the backup battery is charged.
If S153 is not used during about half a year, the backup battery becomes empty. When the
backup battery empties, the preserved data is lost. When a warning mark
is displayed, turn
on the power supply of S153 to charge with the backup battery before the backup battery
empties.
9.4. Storing and Shipping
To maintain optimum operating reliability, do not store the S153 Ver.2 fusion splicer in locations
where the temperature falls below -40°C or rises above +60°C. Also, avoid any environmen tal
conditions that can result in internal condensation. Ensure that the cords are disconnected and
the batteries are removed from machine’s main body when storing the fusion splicer. Ensure
that these temperatures and humidity requirements are also met whenever the S153 Ver.2
fusion splicer is shipped.
Содержание S153 Ver.2
Страница 2: ......
Страница 8: ......
Страница 22: ......
Страница 28: ......
Страница 40: ...External Description 5 2 Electrode V Groove Fiber Holder Fiber Clamp ...
Страница 49: ...External Description 5 11 Function Menu Function Keys Press to select the corresponding Function Menu ...
Страница 50: ......
Страница 99: ...Programming Guide 8 21 Time chart of heater parameters ...
Страница 152: ......
Страница 158: ...Option 10 6 10 4 Cleaning Brush VGC 01 It is used to remove the garbage that adheres to V groove and the fiber clamp ...
Страница 163: ...Recycling and Disposal For sales and service information contact FURUKAWA ELECTRIC CO LTD or your local representative ...