Programming Guide
8-24
The data structure displayed are as follows;
Data Title
Description
CMNT
Comment of the data, which can be edited.
No.
No. 1 is the data for the last splice and the number increases for older
splices.
Arc Count
Arc Count when splice was performed.
Date
Date and time for the splice performed.
PRGM
Name of Fusion Program.
W.L.
Wavelength
Arc Power
Value of Arc Power
AngL:
Cleave angle of the left fiber.
AngR:
Cleave angle of the right fiber.
AngT:
Relative cleave angle between left and right fibers.
Loss:
Estimated splice loss.
Note:
Error codes and additional arc memo if any. The data with error is
highlighted.
L: Estimated loss exceeds the target value
S: Streak or bubble at the splice point or not spliced
A: Cleave angle exceeds the criteria
C: Cleave end face has excessive defects
+: Additional arc is applied