Programming Guide
9-6
9.2. Maintenance
9.2.1.
Arc Check
Perform an arc check whenever high splice losses are observed (see 7.1.1).
9.2.2.
Electrode Maintenance
Inspect the electrodes for dirt, worn-out and damage before using the fusion splicer. Dust and
other particles can be cleaned off by removing the electrodes from the splicing mechanism and
polishing the surface of each electrode with the electrode sharpener. Over the course of normal
operation, the electrodes can be cleaned & maintained for up to 5,000 splices.
Replace the electrodes if any of the following conditions exist:
•
an electrode is bent
•
an electrode end has become extremely rounded
•
abnormal noise occurs during fusion splicing
When the Arc Counter number exceeds 1,000, the S153 Ver.2 automatically displays a message
to prompt replacing the electrodes at power on. Turn off the switch and replace or clean the
electrodes by using the electrode sharpener. The S153 Ver.2 asks if the electrodes are replaced
after prompting the action. Select “Yes” if replaced and “No” if not. When “Yes” is selected, the
Arc Counter is reset to 0 and the message will not appear at power on. When “No” is selected,
Содержание S153 Ver.2
Страница 2: ......
Страница 8: ......
Страница 22: ......
Страница 28: ......
Страница 40: ...External Description 5 2 Electrode V Groove Fiber Holder Fiber Clamp ...
Страница 49: ...External Description 5 11 Function Menu Function Keys Press to select the corresponding Function Menu ...
Страница 50: ......
Страница 99: ...Programming Guide 8 21 Time chart of heater parameters ...
Страница 152: ......
Страница 158: ...Option 10 6 10 4 Cleaning Brush VGC 01 It is used to remove the garbage that adheres to V groove and the fiber clamp ...
Страница 163: ...Recycling and Disposal For sales and service information contact FURUKAWA ELECTRIC CO LTD or your local representative ...