90
Error Code
Cause of Error
Action
Defect in the image processing system.
Contact service center.
The optics are dirty.
See maintenance chapter.
Visual Error
(The image process
cannot find the clad
line, or find the core
line while inspecting.)
Fiber is dirty.
Start the splice from the
beginning. Make sure to
clean the bare portion of
the fiber.
Inappropriate fiber program is selected.
Check and correct the
program.
Incorrect parameter setting for FOCUS and
FIELD.
Check and correct the
parameters.
Defect in the image processing system.
Contact service center.
Optics is dirty.
See Maintenance chapter.
Spec Out Fiber
(The fiber is out of
applicable range.)
Inappropriate fiber program is selected.
Check and correct the
program.
Cladding diameter is out of applicable
range.
Cannot splice with S124.
Camera Position Error
The position of the built-in camera has been
changed by a strong impact.
Contact service center.
Aligning Error
Defect in the image processing system.
Contact service center.
The optics are dirty.
See maintenance chapter.
Fiber Axis Error
Fiber is dirty.
Start the splice from the
beginning. Make sure to
clean the bare portion of
the fiber.
Fiber is not in the proper position.
Load the fiber at the proper
position.
Defect in the image processing system.
Contact service center.
The optics is dirty.
See maintenance chapter.
MFD Miss Error
Fiber is dirty.
Start the splice from the
beginning. Make sure to
clean the bare portion of
the fiber.
Inappropriate fiber program is selected.
Check and correct the
program.
Содержание S124