![Furukawa electric S124 Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/furukawa-electric/s124/s124_user-manual_2349549058.webp)
57
two programs.
1.
Select “Compare” in the pop-up menu.
2.
Select the program to compare.
3.
The parameters of two programs are displayed. Item name is displayed
in red if parameter is different.
6.6.9 Parameter Table
Parameter Table for Splice
Parameter Name Unit
Description
1
st
Arc Start Power
-
Starting arc power of 1
st
arc discharge.
1
st
Arc End Power
-
Ending arc power of 1
st
arc discharge.
1
st
Arc Duration
ms Arc duration of 1st arc.
2
nd
Arc Start Power
-
Starting arc power of 2
nd
arc discharge.
2
nd
Arc End Power
-
Ending arc power of 2
nd
arc discharge.
2
nd
Arc Duration
ms Arc duration of 2
nd
arc.
Cleaning Offset
-
Additional arc power for cleaning purposes.
Cleaning Duration
ms Arc duration for cleaning.
Pre Arc Duration
ms
Time between arc starting and fibers first
butting.
Gap
µm
Gap for the final alignment position before
splicing.
Z Push Type
-
Fiber movement at the time of arc discharge.
Left Fiber / Right Fiber / Both
Z Push Length
µm
Overlapping distance from fibers first
butting position.
Z Pull Start Time
ms Start Time to pull back the fiber.
Содержание S124